Seismic pounding between adjacent buildings: Identification of parameters, soil interaction issues and mitigation measures
Structural pounding has been observed in many previous earthquakes due to insufficient
gap commonly provided between adjacent structures. The collisions usually generate large …
gap commonly provided between adjacent structures. The collisions usually generate large …
Required building separations and observed seismic pounding on the soft soils of Mexico City
A Tena-Colunga, D Sánchez-Ballinas - Soil Dynamics and Earthquake …, 2022 - Elsevier
In this paper, the authors discuss the extensive structural pounding observed in Mexico City
during the September 19, 2017 earthquake. A critical review of the recommendations …
during the September 19, 2017 earthquake. A critical review of the recommendations …
Analysis of pounding between adjacent buildings founded on different soil types
M Miari, R Jankowski - Soil Dynamics and Earthquake Engineering, 2022 - Elsevier
Earthquake-induced pounding was experienced in many previous earthquakes and it was
found to be a critical issue. This study investigates the effect of pounding between buildings …
found to be a critical issue. This study investigates the effect of pounding between buildings …
Pounding of structures at proximity: A state-of-the-art review
Pounding of structures occurs when two or more structures are within proximity subjected to
extensive lateral loading leading to a collision of structures. The pounding effect can be …
extensive lateral loading leading to a collision of structures. The pounding effect can be …
Comprehensive Review on Seismic Pounding Between Adjacent Buildings and Available Mitigation Measures
Seismic pounding has taken place in several earthquake events since adjacent structures
that lack adequate separation distance usually suffer from repetitive, severe collisions …
that lack adequate separation distance usually suffer from repetitive, severe collisions …
Formulation of Separation Distance to Mitigate Wind-Induced Pounding of Tall Buildings
Structures in proximity subjected to a substantial lateral load (eg, wind and earthquakes) can
lead to a significant hazard known as structural pounding. If not properly mitigated, such …
lead to a significant hazard known as structural pounding. If not properly mitigated, such …
[HTML][HTML] Parametric study on seismic rehabilitation of masonry buildings using FRP based upon 3D non-linear dynamic analysis
E Fathalla, H Salem - Buildings, 2018 - mdpi.com
Unreinforced load-bearing masonry (URM) buildings represent a significant portion of the
non-engineered old buildings in many developing countries aiming to reduce the …
non-engineered old buildings in many developing countries aiming to reduce the …
Discrete element based analyses of structure-reservoir problem for gravity dams
BFS Albostan - 2021 - search.proquest.com
The prediction of the nonlinear behavior of gravity dams under seismic actions is
challenging. Firstly, a clear damage indicator to quantify the performance limits of such …
challenging. Firstly, a clear damage indicator to quantify the performance limits of such …
Torsional earthquake-induced pounding between adjacent buildings founded on different soil types
M Miari, R Jankowski - Journal of Seismology and Earthquake Engineering, 2024 - jsee.ir
This paper investigates the effect of the soil type on the torsional response of buildings
experiencing torsional pounding due to earthquake excitations. Six buildings (one 4-storey …
experiencing torsional pounding due to earthquake excitations. Six buildings (one 4-storey …
Pounding of seismically designed low-rise reinforced concrete frames
C Hansapinyo, P Wongmatar… - Proceedings of the …, 2019 - icevirtuallibrary.com
Substantial damage to buildings from seismic pounding is the result of earthquakes in many
urban areas. This study investigated the effects of pounding in low-rise buildings, which had …
urban areas. This study investigated the effects of pounding in low-rise buildings, which had …