A supercapacitor-based power conditioning system for power quality improvement and uninterruptible power supply

D Casadei, G Grandi, C Rossi - Industrial Electronics, 2002 …, 2002 - ieeexplore.ieee.org
A power conditioning system (PCS) which uses a supercapacitor bank as energy storage
device is proposed as a viable solution for improving the quality and the reliability of the …

Modified control strategy for shunt active power filter with MRAS-based DC voltage estimation and load current sensor reduction

S Sharma, V Verma - IEEE Transactions on Industry …, 2021 - ieeexplore.ieee.org
Failure of any sensor involved in the operation of shunt active power filter (SAPF) not only
degrades its performance but also deteriorates power quality. The purpose of the proposed …

Control strategy for three phase shunt active power filter with minimum current measurements

YP Obulesu - International Journal of Electrical and Computer …, 2011 - search.proquest.com
The active power filter has been proved to be an effective method to mitigate harmonic
currents generated by nonlinear loads as well as to compensate reactive power. The …

The design and implementation of a shunt active power filter based on source current measurement

E Ozdemir, M Ucar, M Kesler… - 2007 IEEE International …, 2007 - ieeexplore.ieee.org
In this study, design and implementation of a shunt active power filter (APF) based on a
simplified control method is given without load and filter current measurement. The …

A simplified control algorithm for shunt active power filter without load and filter current measurement

E Ozdemir, M Ucar, M Kesler… - IECON 2006-32nd Annual …, 2006 - ieeexplore.ieee.org
In this study, a new control algorithm for three-phase shunt active power filter (APF) is
proposed without load and filter current measurement. The proposed control method, based …

[图书][B] Filtros activos de potencia para la compensación instantánea de armónicos y energía reactiva.

M Román Lumbreras - 2006 - upcommons.upc.edu
Desde el último cuarto del pasado siglo, y debido al espectacular incremento de la
conexión de cargas electrónicas al sistema eléctrico, se ha incrementado …

[PDF][PDF] Investigation of shunt active power filter for power quality improvment

M Kmail - NEAR EAST, 2012 - academia.edu
In the recent decades, the world has seen an expansion in the use of non-linear loads.
These loads draw harmonic non-sinusoidal currents and voltages in the connection point …

Behavior of a power conditioner for/spl mu/-SMES systems under unbalanced supply voltages and unbalanced loads

D Casadei, G Grandi, U Reggiani… - ISIE'99. Proceedings …, 1999 - ieeexplore.ieee.org
In this paper a power conditioning system (PCS) is analyzed under input and output
unbalanced conditions. The PCS, which can be utilized as an active filter with additional …

Implementation of shunt active power filter using source voltage and source current detection

U Khruathep… - 2008 3rd IEEE …, 2008 - ieeexplore.ieee.org
This paper presents the implementation of shunt active power filter using source voltage and
source current detection. The harmonic current and reactive power compensation of shunt …

[引用][C] 并联型APF 两种典型控制方式的机制解析