Materials for hip prostheses: a review of wear and loading considerations

M Merola, S Affatato - Materials, 2019 - mdpi.com
Replacement surgery of hip joint consists of the substitution of the joint with an implant able
to recreate the articulation functionality. This article aims to review the current state of the art …

On the matter of synovial fluid lubrication: Implications for Metal-on-Metal hip tribology

C Myant, P Cann - Journal of the mechanical behavior of biomedical …, 2014 - Elsevier
Artificial articular joints present an interesting, and difficult, tribological problem. These
bearing contacts undergo complex transient loading and multi axes kinematic cycles, over …

Specifications for innovative, enabling biomaterials based on the principles of biocompatibility mechanisms

DF Williams - Frontiers in bioengineering and biotechnology, 2019 - frontiersin.org
In any engineering discipline, whenever products are designed, manufactured and
ultimately utilized for the benefits of society, a series of specifications for the product are …

Effect of taper design on trunnionosis in metal on polyethylene total hip arthroplasty

SC Tan, MG Teeter, C Del Balso, JL Howard… - The Journal of …, 2015 - Elsevier
This study examines how taper design affects corrosion and fretting at the head trunnion
surface. All hip prostheses retrieved between 1999 and 2013 with 28 mm/+ 0 heads were …

Classification of biomaterial functionality

A Arjunan, A Baroutaji, AS Praveen, J Robinson… - 2020 - wlv.openrepository.com
The rapid evolution in biomaterial performance over the last decade calls for an ever-
increasing need in the classification of their functionalities. In many cases, emerging …

[HTML][HTML] Does taper size have an effect on taper damage in retrieved metal-on-polyethylene total hip devices?

GB Higgs, DW MacDonald, JL Gilbert… - The Journal of …, 2016 - Elsevier
Background Taper design has been identified as a possible contributor to fretting corrosion
damage at modular connections in total hip arthroplasty systems, but variations in as …

[HTML][HTML] Contact mechanics of modular metal-on-polyethylene total hip replacement under adverse edge loading conditions

X Hua, J Li, L Wang, Z Jin, R Wilcox, J Fisher - Journal of biomechanics, 2014 - Elsevier
Edge loading can negatively impact the biomechanics and long-term performance of hip
replacements. Although edge loading has been widely investigated for hard-on-hard …

Metal ion levels from well-functioning Birmingham Hip Resurfacings decline significantly at ten years

C Van Der Straeten, D Van Quickenborne… - The bone & joint …, 2013 - boneandjoint.org.uk
A retrospective study was conducted to investigate the changes in metal ion levels in a
consecutive series of Birmingham Hip Resurfacings (BHRs) at a minimum ten-year follow …

Hip resurfacing: history, current status, and future

HC Amstutz, MJ Le Duff - Hip International, 2015 - journals.sagepub.com
Hip resurfacing arthroplasty (HRA) presents several advantages over conventional total hip
arthroplasty (THA), including conservation and preservation of bone, reduced risk of …

The contact mechanics and occurrence of edge loading in modular metal-on-polyethylene total hip replacement during daily activities

X Hua, J Li, Z Jin, J Fisher - Medical engineering & physics, 2016 - Elsevier
The occurrence of edge loading in hip joint replacement has been associated with many
factors such as prosthetic design, component malposition and activities of daily living. The …