Control Methodologies to Mitigate and Regulate Second-Order Ripples in DC–AC Conversions and Microgrids: A Brief Review

S Chaturvedi, M Wang, Y Fan, D Fulwani, GV Hollweg… - Energies, 2023 - mdpi.com
Second-order ripples occur in the voltage and current during any DC–AC power conversion.
These conversions occur in the voltage source inverters (VSIs), current source inverters …

Application of three-dimensional unbalanced coordinate transformation to stand-alone four-leg voltage-source inverter

G Tan, J Wei, W Zhao, L Qi… - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
Three-phase four-leg voltage-source inverter has been extensively investigated in recent
years for its compactness, small size, and high efficiency, and it has been proved to be the …

Robust control and optimization method for single-phase grid-connected inverters based on all-pass-filter phase-locked loop in weak grid

L Yang, T Cao, H Chen, X Dong, S Zhang - Energies, 2022 - mdpi.com
In a distributed generation system, the all-pass-filter phase-locked loop (APF-PLL) is a
commonly used method for grid synchronization. However, the coupling effect between APF …

Stability analysis and robust control method for LCL-type three-phase four-wire split capacitor inverter considering zero-sequence loop

L Yang, T Cao, Z Cai, X Xia, C Jia, X Dong, S Zhang - Electronics, 2022 - mdpi.com
In distributed generation systems, the inverter is the main power interface and its stability
directly determines the reliable operation of the grid-connected system. As a typical topology …

[HTML][HTML] An individual sequencing control strategy for three-phase four-leg inverter under unbalanced loads

H Jiang, H Pan, B Shang - Energy Reports, 2023 - Elsevier
Under the influence of the unbalanced load, the negative and zero sequence components in
the output voltage of the three-phase four-leg voltage source inverter (TPFL-VSI) will cause …

Small-signal Stability Analysis of Three-phase Four-wire system Integrated with Single-phase PV Inverters Considering Phase to Phase Coupling

Y Liao, H Nian, H Li, L Chen, B Hu… - IEEE Transactions on …, 2023 - ieeexplore.ieee.org
The single-phase rooftop photovoltaic inverters connected to the three-phase four-wire weak
grid have received plenty of applications, which also brings in small-signal stability issues. In …

Impedance modeling and stability analysis of three-phase four-wire inverter with grid-connected operation

G Feng, Z Ye, Y Xia, L Huang, Z Wang - Energies, 2022 - mdpi.com
With the continuous penetration and development of renewable energy power generation,
distributed grids and microgrids are becoming increasingly important in power systems. In …

Enhancing frequency system damping efficiency via optimal integration of VRE in grid

TA Abderrazak, A Iliace, BM Sofiane… - … on Energy Transition …, 2023 - ieeexplore.ieee.org
This comprehensive study addresses the integration stability of photovoltaic (PV) systems in
the SAIDA-NAAMA region of western Algeria, focusing on dynamic and static …

Overview and Impedance-Based Stability Analyses of Bison Wind Farm: A PRACTICAL EXAMPLE

M Arshad, O Beik, R Pallapati… - IEEE Industry …, 2024 - ieeexplore.ieee.org
This article presents an overview and performs impedance-based stability analyses of Bison
wind farm (BWF), which is the largest wind farm in the state of North Dakota, owned and …

Power Sharing in Three-Level NPC Inverter Based Three-Phase Four-Wire Islanding Microgrids With Unbalanced Loads

B Sharma, PK Pankaj, Y Terriche, A Saim… - IEEE …, 2023 - ieeexplore.ieee.org
The droop-based control schemes are widely used for power-sharing and control of the
isolated microgrids. The conventional droop control scheme with inner current and voltage …