Grid-synchronization stability of converter-based resources—An overview
This paper presents an overview of the synchronization stability of converter-based
resources under a wide range of grid conditions. The general grid-synchronization …
resources under a wide range of grid conditions. The general grid-synchronization …
An overview of assessment methods for synchronization stability of grid-connected converters under severe symmetrical grid faults
Grid-connected converters exposed to weak grid conditions and severe fault events are at
risk of losing synchronism with the external grid and neighboring converters. This …
risk of losing synchronism with the external grid and neighboring converters. This …
Improved weak grids synchronization unit for passivity enhancement of grid-connected inverter
The weak grids may be unstable due to the negative resistance behavior of the grid-
connected inverter (GCI) caused by the synchronization unit with the phase-locked loop …
connected inverter (GCI) caused by the synchronization unit with the phase-locked loop …
Constant-coupling-effect-based PLL for synchronization stability enhancement of grid-connected converter under weak grids
The phase-locked loop (PLL)-caused couplings on the grid-connected converter (GCC) are
strengthened by increasing its bandwidth and then incur synchronization instability. This …
strengthened by increasing its bandwidth and then incur synchronization instability. This …
On the stability of power electronics-dominated systems: Challenges and potential solutions
The modern power system is becoming more complicated due to the ever increasing
penetration of power electronics, which is referred to as a power-electronics-dominated …
penetration of power electronics, which is referred to as a power-electronics-dominated …
A double-PLLs-based impedance reshaping method for extending stability range of grid-following inverter under weak grid
Conventional vector current control scheme has been widely used in grid-connected inverter
systems. However, it suffers from severe power limitation issues under weak grids. This …
systems. However, it suffers from severe power limitation issues under weak grids. This …
Modeling and stability analysis of $ LCL $-type grid-connected inverters: A comprehensive overview
Due to the advantages of superior harmonics attenuation ability and reduced size, the LCL
filter has been widely adopted to interface between the inverter and the grid for improving …
filter has been widely adopted to interface between the inverter and the grid for improving …
An improved virtual inertia control for three-phase voltage source converters connected to a weak grid
The continuous increasing share of power-converter-based renewable energies weakens
the power system inertia. The lack of inertia becomes a main challenge to small-scale …
the power system inertia. The lack of inertia becomes a main challenge to small-scale …
Improved Design of PLL Controller for LCL-Type Grid-Connected Converter in Weak Grid
When LCL-type converter is attached to weak grid, its current control and phase-locked loop
(PLL) will interact with each other, via the point of common coupling voltage. Unfortunately …
(PLL) will interact with each other, via the point of common coupling voltage. Unfortunately …
A distributed power management strategy for multi-paralleled bidirectional interlinking converters in hybrid AC/DC microgrids
For a hybrid ac/dc microgrid (MG), bidirectional interlinking converters (BICs) enable flexible
power interactions between ac and dc subgrids. In each subgrid, power sharing among …
power interactions between ac and dc subgrids. In each subgrid, power sharing among …