Grid-synchronization stability of converter-based resources—An overview

X Wang, MG Taul, H Wu, Y Liao… - IEEE Open Journal …, 2020 - ieeexplore.ieee.org
This paper presents an overview of the synchronization stability of converter-based
resources under a wide range of grid conditions. The general grid-synchronization …

An overview of assessment methods for synchronization stability of grid-connected converters under severe symmetrical grid faults

MG Taul, X Wang, P Davari… - IEEE Transactions on …, 2019 - ieeexplore.ieee.org
Grid-connected converters exposed to weak grid conditions and severe fault events are at
risk of losing synchronism with the external grid and neighboring converters. This …

Improved weak grids synchronization unit for passivity enhancement of grid-connected inverter

X Lin, Y Wen, R Yu, J Yu, H Wen - IEEE Journal of Emerging …, 2022 - ieeexplore.ieee.org
The weak grids may be unstable due to the negative resistance behavior of the grid-
connected inverter (GCI) caused by the synchronization unit with the phase-locked loop …

Constant-coupling-effect-based PLL for synchronization stability enhancement of grid-connected converter under weak grids

X Lin, R Yu, J Yu, H Wen - IEEE Transactions on Industrial …, 2022 - ieeexplore.ieee.org
The phase-locked loop (PLL)-caused couplings on the grid-connected converter (GCC) are
strengthened by increasing its bandwidth and then incur synchronization instability. This …

On the stability of power electronics-dominated systems: Challenges and potential solutions

Q Peng, Q Jiang, Y Yang, T Liu, H Wang… - IEEE Transactions …, 2019 - ieeexplore.ieee.org
The modern power system is becoming more complicated due to the ever increasing
penetration of power electronics, which is referred to as a power-electronics-dominated …

A double-PLLs-based impedance reshaping method for extending stability range of grid-following inverter under weak grid

L Huang, C Wu, D Zhou… - IEEE Transactions on …, 2021 - ieeexplore.ieee.org
Conventional vector current control scheme has been widely used in grid-connected inverter
systems. However, it suffers from severe power limitation issues under weak grids. This …

Modeling and stability analysis of $ LCL $-type grid-connected inverters: A comprehensive overview

Y Han, M Yang, H Li, P Yang, L Xu, EAA Coelho… - IEEE …, 2019 - ieeexplore.ieee.org
Due to the advantages of superior harmonics attenuation ability and reduced size, the LCL
filter has been widely adopted to interface between the inverter and the grid for improving …

An improved virtual inertia control for three-phase voltage source converters connected to a weak grid

J Fang, P Lin, H Li, Y Yang… - IEEE Transactions on …, 2018 - ieeexplore.ieee.org
The continuous increasing share of power-converter-based renewable energies weakens
the power system inertia. The lack of inertia becomes a main challenge to small-scale …

Improved Design of PLL Controller for LCL-Type Grid-Connected Converter in Weak Grid

D Zhu, S Zhou, X Zou, Y Kang - IEEE Transactions on Power …, 2019 - ieeexplore.ieee.org
When LCL-type converter is attached to weak grid, its current control and phase-locked loop
(PLL) will interact with each other, via the point of common coupling voltage. Unfortunately …

A distributed power management strategy for multi-paralleled bidirectional interlinking converters in hybrid AC/DC microgrids

P Lin, P Wang, C Jin, J Xiao, X Li… - IEEE Transactions on …, 2019 - ieeexplore.ieee.org
For a hybrid ac/dc microgrid (MG), bidirectional interlinking converters (BICs) enable flexible
power interactions between ac and dc subgrids. In each subgrid, power sharing among …