Electrical impedance tomography: Tissue properties to image measures
Electrical impedance tomography (EIT) uses electrical stimulation and measurement at the
body surface to image the electrical properties of internal tissues. It has the advantage of …
body surface to image the electrical properties of internal tissues. It has the advantage of …
Reconfigurable FPGA architectures: A survey and applications
P Babu, E Parthasarathy - Journal of The Institution of Engineers (India) …, 2021 - Springer
Reconfigurable computing is a potential paradigm which has been effectively performing
mostly in the developments of devices likely Field Programmable Gate Arrays (FPGAs). This …
mostly in the developments of devices likely Field Programmable Gate Arrays (FPGAs). This …
[HTML][HTML] A versatile and reproducible multi-frequency electrical impedance tomography system
A highly versatile Electrical Impedance Tomography (EIT) system, nicknamed the
ScouseTom, has been developed. The system allows control over current amplitude …
ScouseTom, has been developed. The system allows control over current amplitude …
[HTML][HTML] Multi-frequency electrical impedance tomography and neuroimaging data in stroke patients
Abstract Electrical Impedance Tomography (EIT) is a non-invasive imaging technique, which
has the potential to expedite the differentiation of ischaemic or haemorrhagic stroke …
has the potential to expedite the differentiation of ischaemic or haemorrhagic stroke …
A high frame rate wearable EIT system using active electrode ASICs for lung respiration and heart rate monitoring
A high specification, wearable, electrical impedance tomography (EIT) system with 32 active
electrodes is presented. Each electrode has an application specific integrated circuit (ASIC) …
electrodes is presented. Each electrode has an application specific integrated circuit (ASIC) …
Absolute reconstructions using rotational electrical impedance tomography for breast cancer imaging
A rotational Electrical Impedance Tomography (rEIT) methodology is described and shown
to produce spatially accurate absolute reconstructions with improved image contrast and an …
to produce spatially accurate absolute reconstructions with improved image contrast and an …
[HTML][HTML] A review on electrical impedance tomography spectroscopy
J Padilha Leitzke, H Zangl - Sensors, 2020 - mdpi.com
Electrical Impedance Tomography Spectroscopy (EITS) enables the reconstruction of
material distributions inside an object based on the frequency-dependent characteristics of …
material distributions inside an object based on the frequency-dependent characteristics of …
Development of a portable electrochemical impedance spectroscopy system for bio-detection
Z Jiang, J Yao, L Wang, H Wu, J Huang… - IEEE Sensors …, 2019 - ieeexplore.ieee.org
A portable electrochemical impedance spectroscopy (EIS) system has been developed
based on FPGA for bio-detection. FPGA is a programmable signal processing chip, which …
based on FPGA for bio-detection. FPGA is a programmable signal processing chip, which …
Toward electrical impedance tomography coupled ultrasound imaging for assessing muscle health
EK Murphy, J Skinner, M Martucci… - IEEE transactions on …, 2018 - ieeexplore.ieee.org
This paper establishes for the first time that a coupled ultrasound (US) and electrical
impedance tomography (EIT) system can serve as a non-invasive, spatially localized …
impedance tomography (EIT) system can serve as a non-invasive, spatially localized …
A multichannel real-time bioimpedance measurement device for pulse wave analysis
R Kusche, P Klimach, M Ryschka - IEEE transactions on …, 2018 - ieeexplore.ieee.org
Pulse wave analysis is an important method used to gather information about the
cardiovascular system. Instead of detecting the pulse wave via pressure sensors …