A two-stage modelling approach for the analysis of the stress distribution in anchorage zones of pre-tensioned, concrete elements
R Steensels, L Vandewalle, B Vandoren… - Engineering Structures, 2017 - Elsevier
An innovative strategy for the analysis and design of the anchorage zones of pre-tensioned,
concrete girders is presented. In this approach, the bond behaviour of the prestress strands …
concrete girders is presented. In this approach, the bond behaviour of the prestress strands …
Simulating bond failure in reinforced concrete by a plasticity model
DS Brisotto, E Bittencourt, VMRA Bessa - Computers & structures, 2012 - Elsevier
In this work, an axisymmetric plasticity model is used to simulate the concrete-steel interface
behavior. A nonlocal correction is here introduced in order to capture the degradation of the …
behavior. A nonlocal correction is here introduced in order to capture the degradation of the …
Un-tensioned pullout tests to predict the bond quality of different prestressing reinforcements used in concrete railroad ties
ML Arnold - 2013 - krex.k-state.edu
An experimental testing program was conducted at Kansas State University (KSU) to test the
bond characteristics of various 5.32-mm-diameter steel wires and smaller diameter (less …
bond characteristics of various 5.32-mm-diameter steel wires and smaller diameter (less …
Analytical modelling of a three-layer wall system of strengthening for large-panel slab buildings by means of bonded anchors
JK Szlendak, A Jablonska-Krysiewicz… - MATEC Web of …, 2018 - matec-conferences.org
The goal of the article is to elaboration analytical models describing a new system of
reinforcing three-layer walls of large-panel buildings with bonded anchors. The use of this …
reinforcing three-layer walls of large-panel buildings with bonded anchors. The use of this …
Study of bond stress–slip relationship and radial dilation in prestressed concrete
This paper presents two test procedures for evaluating the bond stress–slip and the slip–
radial dilation relationships when the prestressing force is transmitted by releasing the steel …
radial dilation relationships when the prestressing force is transmitted by releasing the steel …
[PDF][PDF] Finite Element Analysis Of Bond Slip Behavior In Pretensioned Bridge Girder
The transfer of prestress force from prestressing strands to the surrounding concrete is
dependent on the bond between the two materials. It is essential to understand the actual …
dependent on the bond between the two materials. It is essential to understand the actual …
Development of Un-Tensioned Pullout Tests to Determine the Bond Quality of Prestressing Reinforcements Used in Pretensioned Concrete Railroad Ties
ML Arnold, RJ Peterman, BT Beck, CH Wu - 2021 - krex.k-state.edu
An experimental program was conducted at Kansas State University (KSU) to evaluate the
bond characteristics of prestressing wires and strands used in the manufacture of …
bond characteristics of prestressing wires and strands used in the manufacture of …
[图书][B] Experimental determination of prestressing wire bond and splitting propensity characteristics through tensioned pullout tests
JR Holste - 2014 - search.proquest.com
This dissertation describes a testing program to evaluate the bond and splitting propensity
characteristics of 5.32-mm-diameter prestressing wires. Prestressing wire reinforcement is …
characteristics of 5.32-mm-diameter prestressing wires. Prestressing wire reinforcement is …
Estudio de corrosión de estructuras en ambientes con bajos contenidos en oxígeno
E García García - 2021 - docta.ucm.es
El hormigón armado es el material de construcción más utilizado desde el siglo XX. Es un
material muy estudiado y se conocen muy bien sus propiedades en condiciones …
material muy estudiado y se conocen muy bien sus propiedades en condiciones …
Using Tensioned Pullout Tests to Determine the Bond-Slip Relationship and Splitting-Propensity of Reinforcements Used in Pretensioned Concrete Railroad Ties
JR Holste, RJ Peterman, BT Beck, CH Wu - 2021 - krex.k-state.edu
A study was conducted to evaluate the bond and splitting propensity characteristics of 12
different 5.32-mm-diameter prestressing wires used in the production of prestressed …
different 5.32-mm-diameter prestressing wires used in the production of prestressed …