Motion estimation and correction in SPECT, PET and CT
Patient motion impacts single photon emission computed tomography (SPECT), positron
emission tomography (PET) and x-ray computed tomography (CT) by giving rise to …
emission tomography (PET) and x-ray computed tomography (CT) by giving rise to …
Synergistic motion compensation strategies for positron emission tomography when acquired simultaneously with magnetic resonance imaging
I Polycarpou, G Soultanidis… - … Transactions of the …, 2021 - royalsocietypublishing.org
Subject motion in positron emission tomography (PET) is a key factor that degrades image
resolution and quality, limiting its potential capabilities. Correcting for it is complicated due to …
resolution and quality, limiting its potential capabilities. Correcting for it is complicated due to …
Motion correction methods for MRS: experts' consensus recommendations
OC Andronesi, PK Bhattacharyya, W Bogner… - NMR in …, 2021 - Wiley Online Library
Long acquisition times due to intrinsically low signal‐to‐noise ratio and the need for highly
homogeneous B0 field make MRS particularly susceptible to motion or scanner instability …
homogeneous B0 field make MRS particularly susceptible to motion or scanner instability …
Comparison of prospective and retrospective motion correction in 3D‐encoded neuroanatomical MRI
JM Slipsager, SL Glimberg, L Højgaard… - Magnetic resonance …, 2022 - Wiley Online Library
Purpose To compare prospective motion correction (PMC) and retrospective motion
correction (RMC) in Cartesian 3D‐encoded MPRAGE scans and to investigate the effects of …
correction (RMC) in Cartesian 3D‐encoded MPRAGE scans and to investigate the effects of …
[HTML][HTML] Quantifying MR head motion in the Rhineland Study–A robust method for population cohorts
Head motion during MR acquisition reduces image quality and has been shown to bias
neuromorphometric analysis. The quantification of head motion, therefore, has both …
neuromorphometric analysis. The quantification of head motion, therefore, has both …
Tracking of rigid head motion during MRI using an EEG system
M Laustsen, M Andersen, R Xue… - Magnetic …, 2022 - Wiley Online Library
Purpose To demonstrate a novel method for tracking of head movements during MRI using
electroencephalography (EEG) hardware for recording signals induced by native imaging …
electroencephalography (EEG) hardware for recording signals induced by native imaging …
Prospective motion correction for diffusion weighted EPI of the brain using an optical markerless tracker
J Berglund, A van Niekerk, H Rydén… - Magnetic …, 2021 - Wiley Online Library
Purpose To enable motion‐robust diffusion weighted imaging of the brain using well‐
established imaging techniques. Methods An optical markerless tracking system was used …
established imaging techniques. Methods An optical markerless tracking system was used …
Data-driven respiratory phase-matched PET attenuation correction without CT
We propose a deep learning-based data-driven respiratory phase-matched gated-PET
attenuation correction (AC) method that does not need a gated-CT. The proposed method is …
attenuation correction (AC) method that does not need a gated-CT. The proposed method is …
Marker‐free optical stereo motion tracking for in‐bore MRI and PET‐MRI application
Purpose Prospective motion correction is arguably the “silver bullet” solution for magnetic
resonance imaging (MRI) studies impacted by motion, applicable to almost any pulse …
resonance imaging (MRI) studies impacted by motion, applicable to almost any pulse …
Brain PET motion correction using 3D face-shape model: the first clinical study
Y Iwao, G Akamatsu, H Tashima, M Takahashi… - Annals of Nuclear …, 2022 - Springer
Objective Head motions during brain PET scan cause degradation of brain images, but head
fixation or external-maker attachment become burdensome on patients. Therefore, we have …
fixation or external-maker attachment become burdensome on patients. Therefore, we have …