[HTML][HTML] The hysteresis Bouc-Wen model, a survey

M Ismail, F Ikhouane, J Rodellar - Archives of computational methods in …, 2009 - Springer
Structural systems often show nonlinear behavior under severe excitations generated by
natural hazards. In that condition, the restoring force becomes highly nonlinear showing …

[HTML][HTML] Hierarchical semi-active control of base-isolated structures using a new inverse model of magnetorheological dampers

A Bahar, F Pozo, L Acho, J Rodellar, A Barbat - Computers & structures, 2010 - Elsevier
Magnetorheological (MR) dampers have received special attention as semi-active devices
for mitigation of structural vibrations. Because of the inherent nonlinearity of these devices, it …

Neural-network control of a stand-alone tall building-like structure with an eccentric load: An experimental investigation

H Gao, W He, L Zhang, C Sun - IEEE Transactions on …, 2020 - ieeexplore.ieee.org
This article develops a finite-dimensional dynamic model to describe a stand-alone tall
building-like structure with an eccentric load by using the assumed mode method (AMM). To …

Structural control benchmark problem: Phase II—Nonlinear smart base‐isolated building subjected to near‐fault earthquakes

S Nagarajaiah, S Narasimhan… - Structural Control and …, 2008 - Wiley Online Library
Many branches of engineering, mathematics, and sciences, have relied on benchmark
problems as a standard means to compare different solution techniques. Since 1996, the …

Force‐derivative feedback semi‐active control of base‐isolated buildings using large‐scale MR fluid dampers

A Rodríguez, F Pozo, A Bahar, L Acho… - … Control and Health …, 2012 - Wiley Online Library
This paper investigates the effectiveness of force‐derivative feedback semi‐active control
control scheme for seismic protection of base‐isolated building structures employing …

[HTML][HTML] Passive and hybrid mitigation of potential near-fault inner pounding of a self-braking seismic isolator

M Ismail, J Rodellar, F Pozo - Soil Dynamics and Earthquake Engineering, 2015 - Elsevier
A seismic isolated structure is usually a long-period structural system, which may encounter
a low-frequency resonance problem when subjected to a near-fault earthquake that usually …

[HTML][HTML] Inner pounding control of the RNC isolator and its impact on seismic isolation efficiency under near-fault earthquakes

M Ismail - Engineering Structures, 2015 - Elsevier
The recently proposed Roll-in-Cage (RNC) isolator, with an inherent self-stopping
mechanism, is used herein for protection against near-fault earthquakes and to …

Active and semi-active strategies to control building structures under large earthquake motion

M Morales-Beltran, J Paul - Journal of Earthquake Engineering, 2015 - Taylor & Francis
As of today, about 80 buildings equipped with active or semi-active devices for wind and
earthquake-induced motion control have been reported. In the first part of this technical note …

Adaptive block backstepping control for civil structures with unknown parameters subjected to seismic excitation

P Ghaderi, F Amini - Structural control and health monitoring, 2017 - Wiley Online Library
This paper presents an active control scheme for structures with unknown parameters
subjected to ground acceleration. It is assumed that the mass, stiffness and damping …

Multiaxial active isolation for seismic protection of buildings

CM Chang, BF Spencer Jr, P Shi - Structural Control and …, 2014 - Wiley Online Library
Passive isolation has been widely accepted as an effective means for the protection of
structures against seismic hazards. The isolation bearings, typically placed at the base of the …