Aerosol transmission in queuing and dining scenarios in canteens and the effectiveness of control measures
This study investigates the aerosol transmission in queuing and dining scenarios in
canteens and explores the effectiveness of control measures. An improved Wells-Riley …
canteens and explores the effectiveness of control measures. An improved Wells-Riley …
Strategic ventilation design for reducing airborne infection transmission in a two-story building: A numerical approach
Abstract This study employs Computational Fluid Dynamics (CFD) to assess the impact of
various ventilation configurations on respiratory droplet dispersion in a two-story restaurant …
various ventilation configurations on respiratory droplet dispersion in a two-story restaurant …
Evaluation of cooling energy saving and ventilation renovations in office buildings by combining bioclimatic design strategies with CFD-BEM coupled simulation
X Yin, MW Muhieldeen - Journal of Building Engineering, 2024 - Elsevier
Bioclimatic design knowledge and measures, including passive techniques and natural
ventilation cooling, are urgently for building renovation to mitigate global warming. The …
ventilation cooling, are urgently for building renovation to mitigate global warming. The …
[HTML][HTML] A numerical framework for the analysis of indoor air quality in a classroom
MMA Mahmoud, P Bahl, AFVA Aquino… - Journal of Building …, 2024 - Elsevier
This paper presents a framework for applying Computational Fluid Dynamics (CFD) to study
indoor air quality in a classroom environment by analysing the transport and extent of …
indoor air quality in a classroom environment by analysing the transport and extent of …
Numerical study of different ventilation schemes in a classroom for efficient aerosol control
A Ugarte-Anero, U Fernandez-Gamiz, K Portal-Porras… - Heliyon, 2023 - cell.com
The air quality is a parameter to be controlled in order to live in a comfortable place. This
paper analyzes the trajectory of aerosols exhaled into the environment in a classroom …
paper analyzes the trajectory of aerosols exhaled into the environment in a classroom …
Assessment of infection probability indices for airborne diseases in confined spaces: combination of CFD and analytical modelling
M Piller, G Bulian, CA Stival - Journal of Building Performance …, 2024 - Taylor & Francis
The paper presents a framework for probabilistic assessment of likelihood of infection from
airborne diseases in confined spaces which are continuously occupied for relatively long …
airborne diseases in confined spaces which are continuously occupied for relatively long …
Indoor air modelling and infection risk assessment in a naturally ventilated patient room
Sufficient ventilation in clinics is critical for diluting virus concentrations and lowering
subsequent doses inhaled by the occupants. Several advanced simulation methods and …
subsequent doses inhaled by the occupants. Several advanced simulation methods and …
[引用][C] Sistemas de ventilación en espacios cerrados para un control eficiente de aerosoles.
A Ugarte Anero - 2023