Seismic performance of RC joints retrofitted by external diagonal bolts

E Tavasoli, O Rezaifar, A Kheyroddin - Journal of Building Engineering, 2022 - Elsevier
Reinforced concrete beam-column joints play a key role in transferring gravity and lateral
loads from beam to column. One of the main failures of the RC joints is shear failure due to a …

Experimental study discussion of the seismic behavior on new types of internal/external stiffeners in rigid beam-to-CFST/HSS column connections

O Rezaifar, A Younesi - Construction and Building Materials, 2017 - Elsevier
The use of box columns has been increased due to the rigidity of rigid orthogonal moment
resisting frames. On the other hand, the installation and welding of necessary horizontal …

Structural health monitoring of a concrete-filled tube column

A Younesi, O Rezaifar, M Gholhaki… - Magazine of Civil …, 2019 - engstroy.spbstu.ru
Structural Health Monitoring (SHM) has provided an opportunity to assess the reliability and
integrity of civil engineering structures. Damage in the structure reduces the hardness and …

Seismic behavior of through beam connection to steel box-column

FJ Paghaleh, MA Hadianfard, H Saffari - Journal of Constructional Steel …, 2022 - Elsevier
Due to its many advantages, it is highly desirable to use box columns in steel structures.
However, despite the numerous advantages box columns offer, it is always difficult to …

Experimental seismic behaviour of L-CFST column to H-beam connections

W Zhang, ZH Chen, Q Xiong, T Zhou, X Rong… - Steel and Composite …, 2018 - dbpia.co.kr
In this study, the seismic performance of the connections between L-shaped columns
composed of concrete-filled steel tubes (L-CFST columns) and H-beams used in high-rise …

[PDF][PDF] Experimental study of rigid beam-to-box column connections with types of internal/external stiffeners

O Rezaifar, M Nazari, M Gholhaki - Steel and Composite …, 2017 - researchgate.net
Box sections are symmetrical sections and they have high moment of inertia in both
directions, therefore they are good members in tall building structures. For the rigid …

Active interface debonding detection of a Concrete Filled Tube (CFT) column by modal parameters and Continuous Wavelet Transform (CWT) technique

A Younesi, O Rezaifar, M Gholhaki… - Structural Monitoring …, 2021 - koreascience.kr
In recent years, damage detection methods have been significantly increased in civil and
mechanical structures. One of the most widely used and relatively new methods of signal …

Damage detection in concrete filled tube columns based on experimental modal data and wavelet technique

A Younesi, O Rezaeifar, M Gholhaki… - Mechanics of …, 2020 - macs.semnan.ac.ir
Damage detection in Concrete-Filled Tubes (CFSTs) and the study of their application in
special structures such as high-rise buildings, towers and bridges are important issues …

Experimental and Numerical Investigation of Concrete‐Filled Double‐Skin Steel Tubular Column for Steel Beam Joints

D Zhang, J Zhao, Y Zhang - Advances in Materials Science …, 2018 - Wiley Online Library
This paper presents a new type of joint for connecting steel beams with a concrete‐filled
double‐skin steel tubular (CFDST) column. Four half‐scale specimens of the joint with …

[PDF][PDF] Debbonding damage detection in concrete filled tube columns by experimental modal data

O Rezayfar, A Younesi, M Gholhaki… - Journal of Structural and …, 2019 - jsce.ir
CFT column significantly used in tall building and bridges due to high load bearing capacity.
Considering the importance and position of these types of columns in structural engineering …