Surface-sensitive and surface-specific ultrafast two-dimensional vibrational spectroscopy
Ultrafast two-dimensional infrared spectroscopy (2D IR) has been advanced in recent years
toward measuring signals from only a monolayer of sample molecules at solid–liquid and …
toward measuring signals from only a monolayer of sample molecules at solid–liquid and …
[图书][B] Encyclopedia of chemical physics and physical chemistry
JH Moore, ND Spencer - 2001 - api.taylorfrancis.com
Jacket illustration. CryoSEM micrograph of a freeze-fractured yeast cell. Specimen was
prepared according to Walther et al (1995) and imaged using back-scattered electrons …
prepared according to Walther et al (1995) and imaged using back-scattered electrons …
Higher-order correlation on polarization beats in Markovian stochastic fields
Y Zhang, CB de Araújo, EE Eyler - Physical Review A, 2001 - APS
The correlation effects of sixth order on cascade three-level polarization beats are
investigated using chaotic field, phase-diffusion, and Gaussian-amplitude models. The …
investigated using chaotic field, phase-diffusion, and Gaussian-amplitude models. The …
On the role of classical field time correlations in noisy light spectroscopy: color locking and a spectral filter analogy
DJ Ulness - The Journal of Physical Chemistry A, 2003 - ACS Publications
Physical concepts which have proven to be of substantial aid in the understanding of the
underlying physical mechanisms of noisy light spectroscopy are established and discussed …
underlying physical mechanisms of noisy light spectroscopy are established and discussed …
Time‐resolved coherent Raman spectroscopy controlled by spectrally tailored noisy light
MJ Stimson, DJ Ulness… - Journal of Raman …, 1997 - Wiley Online Library
A new type of frequency‐and time‐resolved coherent Raman scattering (CRS) spectroscopy
using broadband non‐transform limited noisy light is presented. The noisy light source is …
using broadband non‐transform limited noisy light is presented. The noisy light source is …
Rayleigh-enhanced attosecond sum-frequency polarization beats via twin color-locking noisy lights
Y Zhang, C Gan, L Li, R Ma, J Song, T Jiang, X Yu… - Physical Review A …, 2005 - APS
Based on color-locking noisy field correlation, a time-delayed method is proposed to
suppress the thermal effect, and the ultrafast longitudinal relaxation time can be measured …
suppress the thermal effect, and the ultrafast longitudinal relaxation time can be measured …
Down-conversion of electronic frequencies and their dephasing dynamics: interferometric four-wave-mixing spectroscopy with broadband light
JC Kirkwood, AC Albrecht - Physical Review A, 2000 - APS
The theory for temporally multidimensional, electronically resonant four-wave-mixing (FWM)
spectroscopy based on broadband light interferometry is developed. Both homodyne and …
spectroscopy based on broadband light interferometry is developed. Both homodyne and …
Raman-enhanced polarization beats in Markovian stochastic fields
Y Zhang, C Gan, K Lu, C Li, X Hou - Optics communications, 2002 - Elsevier
Raman-enhanced polarization beats (REPBs) with broadband noisy light are investigated
using chaotic field, phase-diffusion, and Gaussian-amplitude models. The polarization beat …
using chaotic field, phase-diffusion, and Gaussian-amplitude models. The polarization beat …
Coherent Raman scattering with incoherent light for a multiply resonant mixture: a factorized time correlator diagram analysis
JC Kirkwood, AC Albrecht, DJ Ulness, MJ Stimson - Physical Review A, 1998 - APS
Coherent Raman scattering using broadband, incoherent (noisy) light (termed I (2) CRS—
the I for interferometric and the superscript 2 for twice acting noisy fields) is treated for a …
the I for interferometric and the superscript 2 for twice acting noisy fields) is treated for a …
Effects of beam polarization on coherent anti‐Stokes Raman scattering using noisy light
PP Aung, KM Cosert, LR Weisel… - Journal of Raman …, 2005 - Wiley Online Library
The effects of different linear polarization schemes on the noisy light‐based coherent anti‐
Stokes Raman scattering [I (2) CARS] signal were investigated. It was found that certain …
Stokes Raman scattering [I (2) CARS] signal were investigated. It was found that certain …