[HTML][HTML] Beam-to-CFST column joints in steel-concrete composite buildings: A comprehensive review

HT Thai - Structures, 2024 - Elsevier
With structural and economic benefits, concrete filled steel tubular (CFST) columns have
been widely used in multistorey buildings in which the beam-to-column joints play an …

Analytical model of moment-rotation relation for steel beam to CFST column connections with bidirectional bolts

G Zhou, Y An, D Li, J Ou - Engineering Structures, 2019 - Elsevier
The steel beam to concrete filled steel tube (CFST) column connection with bidirectional
bolts has good seismic performance, and it plays an important role in the semi-rigid …

Initial stiffness of connection joining I-beam to concrete-filled multicellular steel tube wall

Z Hu, J He, G Tong, Y Chen, G Zhang - Journal of Constructional Steel …, 2023 - Elsevier
Concrete-filled multicellular steel tube (CF-MCST) wall is widely used in China in recent
years. In the companion paper, the moment capacity of the connection joining an I-beam to a …

Moment-rotation model of endplate blind bolted joints with CFST column

J Fan, J Zhao, W Gao - Journal of Constructional Steel Research, 2021 - Elsevier
The moment-rotation curves can directly reflect the performance of H-shaped beam to
concrete filled steel tube (CFST) column joints, which should be fully considered in structure …

An intelligent prediction system for predicting the types of joints on extended endplate long bolted joint using fuzzy rules

M SenthilPandian, MH Santhi, S Ganapathy… - Soft Computing, 2024 - Springer
Digitalization occupies entire world irrespective of the fields including the construction field
study and it plays a major role to identify the better structure using the various design …

Experimental investigation and analytical modeling of steel beam-to-CFDST column connection

J Fan, J Zhao - Journal of Constructional Steel Research, 2022 - Elsevier
In this paper, a prefabricated connection between concrete-filled double-skin steel tubular
(CFDST) column and steel beam with flush endplates and bidirectional bolts was …

Tube wall deformation behaviour of tensile-loaded blind-bolted connections in octagonal hollow section tubes

F Xu, Y Cai, TM Chan, B Young - Thin-Walled Structures, 2023 - Elsevier
The structural behaviour of octagonal hollow section (OctHS) tubes under lateral tensile
loads applied through blind-bolted T-stubs were experimentally and numerically …

Cyclic behaviour of a novel steel beam-to-prefabricated CFST column connection with threaded sleeve bolts

HQ Liu, YZ Liu, JS Huo, DJ Zhu - Structures, 2021 - Elsevier
As the conventional connection configurations of the steel beam to concrete-filled steel
tubular (CFST) column are complex and unfriendly in practice, the application of the blind …

Moment-rotation model of composite connection with curved endplate and blind bolts

J Fan, J Zhao - Journal of Constructional Steel Research, 2021 - Elsevier
The endplate blind bolted connection is a common type in concrete-filled circle steel tube
(CFCST) structures. The moment-rotation relationship describes the mechanical …

H 型钢梁与矩形钢管混凝土柱平齐式端板单边螺栓连接节点弯矩-转角分析模型.

赵均海, 樊军超, 高伟琪 - … Mechanics/Gongcheng Lixue, 2021 - search.ebscohost.com
为预测通过平齐端板和单边螺栓连接的钢管混凝土节点的弯矩-转角关系,
该文提出基于极限弯矩, 初始转动刚度和形状参数的三参数指数模型. 考虑节点的可能破坏模式 …