[PDF][PDF] VAR Compensation on Load Side using Thyristor Switched Capacitor and Thyristor Controlled Reactor.

B Bimali, S Uprety, RP Pandey - Journal of the Institute of …, 2021 - academia.edu
Generally, AC loads are the inductive loads which are reactive in nature. These loads, thus,
demand and draw reactive power from the supply source. If these loads draw large lagging …

A low-cost microcontroller-based prototype design for power factor improvement in transmission line using thyristor switched capacitor scheme

P Sen, KP Panda, S Rout - … for Smart-City Energy Security and …, 2018 - ieeexplore.ieee.org
When the reactive power demand increases it leads to poor power factor and thus
increasing the losses more. So reducing losses as well as for improvement of power factor, a …

[PDF][PDF] Comparative Analysis of Shunt Capacitor Banks and Static Var Compensators Performance on Distribution Network

SO Edward, P Elechi - International Journal of Analysis of Electrical …, 2020 - academia.edu
Power system losses and voltage stability are twin challenges utilities all over the world are
scrambling to tackle especially in places like Africa and Asia. This research is centered on …

A Topology for Reactive Power Compensation in Grid System Using a Low-Cost Thyristor Switched Capacitor Scheme

G Shrivastava, S Chandra - … on Power Engineering and Intelligent Systems …, 2023 - Springer
The device described in this publication is a thyristor-switched capacitor (TSC) device used
in a 200 kV/11 kV, 200 MW grid system. In addition to the capacitor bank's transient-free …

[PDF][PDF] Impact of the hybrid reactive power compensator on the power grid used a fuzzy PI regulator

A Rahmouni - International Journal of Power Electronics and Drive …, 2021 - academia.edu
The work presented in this article is a contribution to the problem of controlling reactive
powers and voltages in an electrical network. Among these control tools, the static reactive …

Enhancement of Voltage Stability by Using SVC for 30-Bus Power System

DH Amin - Kurdistan Journal of Applied Research, 2019 - spu.edu.iq
Voltage stability refers to maintaining the value of the voltage in all busses of the electric
network at a steady level (initial operating point) during any sudden disturbance. Voltage …

[PDF][PDF] Automatic power factor correction utilizing reactive power compensation for three-phase systems

M Ali, F Rashid, S Rasheed, A Ghous… - Indonesian Journal of …, 2020 - academia.edu
For all industrial and distribution sites, the lagging power factor of electrical loads is a
common problem. In the early days, it was corrected manually by adding the capacitor banks …