Stable pit formation on AA2024-T3 in a NaCl environment
Scanning vibrating electrode (SVE), particle induced X-ray emission spectroscopy (PIXE)
and standard electrochemical measurements were used to study the establishment of stable …
and standard electrochemical measurements were used to study the establishment of stable …
Corrosion of AA2024-T3 Part II: Co-operative corrosion
Polished specimens of AA2024-T3 alloy were immersed for up to 120min in 0.1 M NaCl. The
development of corrosion was monitored using scanning electron microscopy with energy …
development of corrosion was monitored using scanning electron microscopy with energy …
Beam optics in nuclear microprobe: A review
AG Ponomarev, AA Ponomarov - … and Methods in Physics Research Section …, 2021 - Elsevier
The beam optics in a nuclear microprobe is considered on the basis of quality criteria for
focusing systems. In this consideration, empirical criteria with dominant chromatic or intrinsic …
focusing systems. In this consideration, empirical criteria with dominant chromatic or intrinsic …
PIXE and the nuclear microprobe: Tools for quantitative imaging of complex natural materials
CG Ryan - Nuclear Instruments and Methods in Physics Research …, 2011 - Elsevier
The 40year history of nuclear microscopy has seen sustained progress in the development
of technology needed to improve PIXE analysis and trace element imaging performance …
of technology needed to improve PIXE analysis and trace element imaging performance …
An examination of the composition and microstructure of coarse intermetallic particles in AA2099-T8, including Li detection
Electron and proton microprobes, along with electron backscatter diffraction (EBSD) analysis
were used to study the microstructure of the contemporary Al–Cu–Li alloy AA2099-T8. In …
were used to study the microstructure of the contemporary Al–Cu–Li alloy AA2099-T8. In …
[HTML][HTML] Characterising the Pelletron beam at the University of Melbourne
Abstract The Pelletron at the University of Melbourne is a DC particle accelerator that has
been used for materials analysis and ion implantation since its installation in the 1970s …
been used for materials analysis and ion implantation since its installation in the 1970s …
Influence of the beam current density distribution on the spatial resolution of a nuclear microprobe
AA Ponomarov, VI Miroshnichenko… - Nuclear Instruments and …, 2009 - Elsevier
The paper discusses the effect of nonuniform distribution of the ion beam phase density on
the nuclear microprobe resolution. The deconvolution of the beam brightness distribution …
the nuclear microprobe resolution. The deconvolution of the beam brightness distribution …
Focusing giga-electronvolt heavy ions to micrometers at the Institute of Modern Physics
L Sheng, G Du, J Guo, R Wu, M Song… - Review of Scientific …, 2013 - pubs.aip.org
To study the radiation effect of cosmic heavy ions of low fluxes in electronics and living
samples, a focusing heavy ion microbeam facility, for ions with energies of several MeV/u up …
samples, a focusing heavy ion microbeam facility, for ions with energies of several MeV/u up …
A comparison of ray-tracing software for the design of quadrupole microbeam systems
S Incerti, RW Smith, M Merchant, GW Grime… - Nuclear Instruments and …, 2005 - Elsevier
For many years the only ray-tracing software available with sufficient precision for the design
of quadrupole microbeam focusing systems has been OXRAY and its successor TRAX …
of quadrupole microbeam focusing systems has been OXRAY and its successor TRAX …
Design of the IMP microbeam irradiation system for 100 MeV/u heavy ions
S Li-Na, S Ming-Tao, Z Xiao-Qi, Y Xiao-Tian… - Chinese …, 2009 - iopscience.iop.org
A state-of-the-art high energy heavy ion microbeam irradiation system is constructed at the
Institute of Modern Physics of the Chinese Academy of Sciences. This microbeam system …
Institute of Modern Physics of the Chinese Academy of Sciences. This microbeam system …