[图书][B] Intensity modulated radiation therapy: a clinical overview

IJ Das, NJ Sanfilippo, A Fogliata, L Cozzi - 2020 - iopscience.iop.org
Intensity modulated radiation therapy (IMRT) has become standard of care for most cancer
sites that are managed by radiation therapy. This book documents the evolution of this …

[PDF][PDF] The importance of accurate treatment planning, delivery, and dose verification

J Malicki - Reports of Practical Oncology and Radiotherapy, 2012 - journals.viamedica.pl
In recent years, the spectacular technological advances in radiotherapy have generated
much enthusiasm. 1 N ewer techniques take advantage of increased computing power and …

Integral dose: Comparison between four techniques for prostate radiotherapy

K Ślosarek, W Osewski, A Grządziel… - Reports of Practical …, 2015 - journals.viamedica.pl
Aim Comparisons of integral dose delivered to the treatment planning volume and to the
whole patient body during stereotactic, helical and intensity modulated radiotherapy of …

Dosimetric influence of filtered and flattening filter free photon beam on rapid arc (RA) radiotherapy planning in case of cervix carcinoma

L Kumar, G Yadav, KR Samuvel… - Reports of practical …, 2017 - journals.viamedica.pl
Aim To investigate the dosimetric influence of filtered and flattening filter free (FFF) photon
beam of 6 and 10 [[ce: hsp sp=" 0.25"/]] MV energies on cervix RA radiotherapy planning …

The dosimetric impact of different photon beam energy on RapidArc radiotherapy planning for cervix carcinoma

L Kumar, G Yadav, K Raman… - Journal of Medical …, 2015 - journals.lww.com
The main purpose of this study is to know the effect of three different photon energies viz., 6,
10, and 15 mega voltage (MV) on RapidArc (RA) planning for deep-seated cervix tumor and …

Evaluation of combining bony anatomy and soft tissue position correction strategies for IMRT prostate cancer patients

M Adamczyk, T Piotrowski… - Reports of Practical …, 2012 - journals.viamedica.pl
Background Radiotherapy treatment requires delivering high homogenous dose to target
volume while sparing organs at risk. That is why accurate patient positioning is one of the …

Continuous photon energy modulation in IMRT of pancreatic cancer

X Zhang, F Zhou, B Liu, T Xiong, X Bai, Q Wu - Frontiers in Physics, 2023 - frontiersin.org
Purpose: To develop a novel IMRT optimization method based on the principle of photon
energy synthesis that simultaneously optimizes fluence map and beamlet energy. The …

Clinical implications of Eclipse analytical anisotropic algorithm and Acuros XB algorithm for the treatment of lung cancer

GS Krishna, V Srinivas, PY Reddy - Journal of medical physics, 2016 - journals.lww.com
The aim of the present study was to investigate the dose-volume variations of planning
target volume (PTV) and organs at risks (OARs) in 15 left lung cancer patients comparing …

Distribusi Dosis Radiasi Foton pada Treatment Planning System Menggunakan Teknik 3DCRTdan IMRT untuk Terapi Kanker Serviks

A Effina - Jurnal Fisika Unand, 2022 - jfu.fmipa.unand.ac.id
Telah dilakukan penelitian mengenai distribusi dosis radiasi foton pada Treatment Planning
System  (TPS) menggunakan teknik Three Dimension Conformal Radiotherapy (3DCRT) …

Dosimetric analysis of Co-60 source based high dose rate (HDR) brachytherapy: A case series of ten patients with carcinoma of the uterine cervix

OP Gurjar, M Batra, P Bagdare… - Reports of Practical …, 2016 - journals.viamedica.pl
Aim To analyse the dosimetric parameters of Co-60 based high dose rate (HDR)
brachytherapy plans for patients of carcinoma uterine cervix. Background Co-60 high dose …