Methods and analyzers for hemoglobin measurement in clinical laboratories and field settings

RD Whitehead Jr, Z Mei, C Mapango… - Annals of the New …, 2019 - Wiley Online Library
This paper describes and compares methods and analyzers used to measure hemoglobin
(Hb) in clinical laboratories and field settings. We conducted a literature review for methods …

[HTML][HTML] An intelligent non-invasive system for automated diagnosis of anemia exploiting a novel dataset

G Dimauro, ME Griseta, MG Camporeale… - Artificial Intelligence in …, 2023 - Elsevier
Anemia is a condition in which the oxygen-carrying capacity of red blood cells is insufficient
to meet the body's physiological needs. It affects billions of people worldwide. An early …

Comparison of invasive and noninvasive blood hemoglobin measurement in the operating room: a systematic review and meta-analysis

H Shabaninejad, N Ghadimi, K Sayehmiri… - Journal of …, 2019 - Springer
Noninvasive hemoglobin (Hb)-monitoring devices are new inventions in pulse oximeter
systems that show hemoglobin levels continuously. The aim of this systematic review and …

Effect of hyperbilirubinemia on the accuracy of continuous non-invasive hemoglobin measurements in liver transplantation recipients

SB Yoon, CW Jung, T Kim, HC Lee - Scientific Reports, 2024 - nature.com
This study evaluated the effect of hyperbilirubinemia on the accuracy of continuous non-
invasive hemoglobin (SpHb) measurements in liver transplantation recipients. Overall, 1465 …

[HTML][HTML] Noninvasive hematocrit assessment for cardiovascular magnetic resonance extracellular volume quantification using a point-of-care device and synthetic …

S Robison, GR Karur, RM Wald… - Journal of …, 2018 - Elsevier
Background Calculation of cardiovascular magnetic resonance (CMR) extracellular volume
(ECV) requires input of hematocrit, which may not be readily available. The purpose of this …

Development and validation of a photoplethysmography system for noninvasive monitoring of hemoglobin concentration

H Liu, F Peng, M Hu, J Shi, G Wang… - Journal of Electrical …, 2020 - Wiley Online Library
Background. Traditional invasive hemoglobin (Hb) detection led to delayed diagnosis,
operational inefficiency, incorrect critical decision making, and uncomfortable patient …

Accuracy of point-of-care testing devices for haemoglobin in the operating room: meta-analysis

H Ahn, T Lenet, RWD Gilbert, R Mallick, JLV Shaw… - BJS open, 2024 - academic.oup.com
Background Point-of-care tests (POCT) for haemoglobin are increasingly used to guide
intraoperative transfusion. However, their accuracy compared to central laboratory tests is …

Validity of accuracy and trending ability of non-invasive continuous total hemoglobin measurement in complex spine surgery: a prospective cohort study

FC Chang, JR Lin, FC Liu - BMC anesthesiology, 2019 - Springer
Background Patients undergoing complex spine surgery present with multilevel spinal
involvement, advanced age, and multiple comorbidities. Surgery is associated with …

High-precision non-invasive RBC and HGB detection system based on spectral analysis

Y Wang, G Li, L Kong, L Lin - Analytical and Bioanalytical Chemistry, 2023 - Springer
Non-invasive blood composition analysis based on dynamic spectrum (DS) theory has
gained significant attention due to its non-invasive, simple, and fast performance. However …

Accuracy and trending ability of hemoglobin measurement by the Pulse CO-Oximeter during vascular surgery

RC De Rosa, GM Romano, R Abbate… - Journal of Clinical …, 2020 - Springer
Real time information of Hb concentration can guide a tailored patient blood management.
The study investigates the accuracy, precision and trending ability of the Pulse CO-Oximeter …