High-speed optical coherence tomography: basics and applications

M Wojtkowski - Applied optics, 2010 - opg.optica.org
In the past decade we have observed a rapid development of ultrahigh-speed optical
coherence tomography (OCT) instruments, which currently enable performing cross …

Optical coherence tomography–development, principles, applications

AF Fercher - Zeitschrift für Medizinische Physik, 2010 - Elsevier
This paper presents a review of the development of optical coherence tomography (OCT), its
principles and important applications. Basic OCT systems are described and the physical …

Ultrahigh speed 1050nm swept source/Fourier domain OCT retinal and anterior segment imaging at 100,000 to 400,000 axial scans per second

B Potsaid, B Baumann, D Huang, S Barry, AE Cable… - Optics express, 2010 - opg.optica.org
We demonstrate ultrahigh speed swept source/Fourier domain ophthalmic OCT imaging
using a short cavity swept laser at 100,000-400,000 axial scan rates. Several design …

Retinal, anterior segment and full eye imaging using ultrahigh speed swept source OCT with vertical-cavity surface emitting lasers

I Grulkowski, JJ Liu, B Potsaid, V Jayaraman… - Biomedical optics …, 2012 - opg.optica.org
We demonstrate swept source OCT utilizing vertical-cavity surface emitting laser (VCSEL)
technology for in vivo high speed retinal, anterior segment and full eye imaging. The MEMS …

Noncontact depth-resolved micro-scale optical coherence elastography of the cornea

S Wang, KV Larin - Biomedical optics express, 2014 - opg.optica.org
High-resolution elastographic assessment of the cornea can greatly assist clinical diagnosis
and treatment of various ocular diseases. Here, we report on the first noncontact depth …

Ultra high-speed swept source OCT imaging of the anterior segment of human eye at 200 kHz with adjustable imaging range

M Gora, K Karnowski, M Szkulmowski, BJ Kaluzny… - Optics …, 2009 - opg.optica.org
We present an application of in vivo anterior segment imaging of the human eye with an
ultrahigh speed swept source OCT instrument. For this purpose, a dedicated OCT system …

Handheld optical coherence tomography scanner for primary care diagnostics

W Jung, J Kim, M Jeon, EJ Chaney… - IEEE Transactions …, 2010 - ieeexplore.ieee.org
The goal of this study is to develop an advanced point-of-care diagnostic instrument for use
in a primary care office using handheld optical coherence tomography (OCT). This system …

Optical distortion correction in optical coherence tomography for quantitative ocular anterior segment by three-dimensional imaging

S Ortiz, D Siedlecki, I Grulkowski, L Remon… - Optics express, 2010 - opg.optica.org
A method for three-dimensional 3-D optical distortion (refraction) correction on anterior
segment Optical Coherence Tomography (OCT) images has been developed. The method …

Dynamic OCT measurement of corneal deformation by an air puff in normal and cross-linked corneas

C Dorronsoro, D Pascual, P Pérez-Merino… - Biomedical optics …, 2012 - opg.optica.org
A new technique is presented for the non-invasive imaging of the dynamic response of the
cornea to an air puff inducing a deformation. A spectral OCT instrument combined with an air …

Adaptive optics optical coherence tomography at 1 MHz

OP Kocaoglu, TL Turner, Z Liu, DT Miller - Biomedical optics express, 2014 - opg.optica.org
Image acquisition speed of optical coherence tomography (OCT) remains a fundamental
barrier that limits its scientific and clinical utility. Here we demonstrate a novel multi-camera …