A bidirectional neuromodulation technology for nerve recording and stimulation
Electrical nerve recording and stimulation technologies are critically needed to monitor and
modulate nerve activity to treat a variety of neurological diseases. However, current …
modulate nerve activity to treat a variety of neurological diseases. However, current …
A bioelectric neural interface towards intuitive prosthetic control for amputees
Objective. While prosthetic hands with independently actuated digits have become
commercially available, state-of-the-art human-machine interfaces (HMI) only permit control …
commercially available, state-of-the-art human-machine interfaces (HMI) only permit control …
An analogue front-end model for developing neural spike sorting systems
DY Barsakcioglu, Y Liu, P Bhunjun… - IEEE transactions on …, 2014 - ieeexplore.ieee.org
In spike sorting systems, front-end electronics is a crucial pre-processing step that not only
has a direct impact on detection and sorting accuracy, but also on power and silicon area. In …
has a direct impact on detection and sorting accuracy, but also on power and silicon area. In …
Noise optimization techniques for switched-capacitor based neural interfaces
This paper presents the noise optimization of a novel switched-capacitor (SC) based neural
interface architecture, and its circuit demonstration in a 0.13 μm CMOS process. To reduce …
interface architecture, and its circuit demonstration in a 0.13 μm CMOS process. To reduce …
A wide dynamic range neural data acquisition system with high-precision delta-sigma ADC and on-chip EC-PC spike processor
A high-performance, wide dynamic range, fully-integrated neural interface is one key
component for many advanced bidirectional neuromodulation technologies. In this paper, to …
component for many advanced bidirectional neuromodulation technologies. In this paper, to …
A low-noise, wireless, frequency-shaping neural recorder
This paper presents a low-noise, wireless neural recorder that has a frequency dependent
amplification to remove electrode offset and to attenuate motion artifacts. The recorder has …
amplification to remove electrode offset and to attenuate motion artifacts. The recorder has …
Neuronix enables continuous, simultaneous neural recording and electrical microstimulation
This paper reports a novel neurotechnology (Neuronix) and its validation through
experiments. It is a miniature system-on-chip (SoC) that allows recording with simultaneous …
experiments. It is a miniature system-on-chip (SoC) that allows recording with simultaneous …
An MRI Compatible Data Acquisition Device for Rat Brain Recording Inside 16.4 T Magnet
Concurrent recording of neural activities and functional magnetic resonance imaging (fMRI)
data is useful for studying the neurovascular coupling relationship. This article presents a …
data is useful for studying the neurovascular coupling relationship. This article presents a …
A double-sided, single-chip integration scheme using through-silicon-via for neural sensing applications
CW Chang, LC Chou, PT Huang, SL Wu, SW Lee… - Biomedical …, 2015 - Springer
We present a new double-sided, single-chip monolithic integration scheme to integrate the
CMOS circuits and MEMS structures by using through-silicon-via (TSV). Neural sensing …
CMOS circuits and MEMS structures by using through-silicon-via (TSV). Neural sensing …
Monitoring nerve activity
HA Puryear, J Shimada - US Patent 11,197,716, 2021 - Google Patents
Systems and methods provide interface to a patient's auto nomic nerves via an interior
lumen wall of a blood vessel. Systems can include a probe having at least one electrode for …
lumen wall of a blood vessel. Systems can include a probe having at least one electrode for …