Current algorithms for computed electron beam dose planning

A Brahme - Radiotherapy and Oncology, 1985 - Elsevier
The field of electron beam dose planning has been in a state of very rapid development
during the last decade. The essentially one-dimensional manual corrections used since the …

An analytic formula for the extrapolated range of electrons in condensed materials

T Tabata, P Andreo, K Shinoda - … and Methods in Physics Research Section …, 1996 - Elsevier
A single analytic formula for the extrapolated range rex of electrons in condensed materials
of atomic numbers from 4 to 92 is given. It has the form of the product of the continuous …

Electron beam dose planning using Gaussian beams energy and spatial scaling with inhomogeneities

I Lax, A Brahme - Acta Radiologica: Oncology, 1985 - Taylor & Francis
The penetration of an electron beam in matter is characterized by only two material
dependent parameters within the range of validity of the small angle diffusion equation …

An algorithm for depth–dose curves of electrons fitted to Monte Carlo data

T Tabata, P Andreo, K Shinoda - Radiation Physics and Chemistry, 1998 - Elsevier
An accurate algorithm has been developed for the depth profiles of energy deposition by
plane-parallel electron beams normally incident on semi-infinite absorbers. The energies of …

Depth profiles of charge deposition by electrons in elemental absorbers: Monte Carlo results, experimental benchmarks and derived parameters

T Tabata, P Andreo, K Shinoda, R Ito - Nuclear Instruments and Methods in …, 1995 - Elsevier
Depth profiles of charge deposition in absorbers irradiated by electrons have been
computed by using the ITS Monte Carlo system version 3.0. Plane-parallel electron beams …

[PDF][PDF] Reflection ratios of electrons and photons from solids

R Ito, P Andreo, T Tabata - Bulletin of University of Osaka …, 1993 - omu.repo.nii.ac.jp
Electron and photon reflection ratios (in number and energy) for ab-sorbers bombarded by
electrons have been computed with the ITS Monte Carlo system version 3, and results are …

Radiation processing dosimetry

WL McLaughlin - Radiation Physics and Chemistry (1977), 1983 - Elsevier
Measurements of ionizing radiation quantities of intense photon and electron radiations are
used to establish quality control of industrial radiation processes. The most important …

Simple method of evaluating absorbed dose in electron-beam processing

T Tabata, R Ito, I Kuriyama, Y Moriuchi - International Journal of Radiation …, 1989 - Elsevier
The use of semiempirical multilayer depth-dose code EDMULT for evaluating the absorbed-
dose coefficient K was studied with a personal computer. When multiplied by the charge per …

Formation of semiconductor epitaxial films by pulse heating crystallization or regrowth

LN Aleksandrov - physica status solidi (a), 1983 - Wiley Online Library
The contemporary state and perspectives of methods used, namely thermodynamical and
kinetical characteristics of amorphous film crystallization and regrowth processes by pulse …

Sloping lifetime control by electron irradiation for 4.5 kV PT-SIThs

Y Morikawa, T Miura, M Kekura… - Proceedings of 9th …, 1997 - ieeexplore.ieee.org
This paper describes the possibility of realizing sloping lifetime control by electron
irradiation. 4500 V class SIThs which have the wider n-base region are irradiated with 1 …