Effects of alloying elements on the corrosion behavior and biocompatibility of biodegradable magnesium alloys: a review
Magnesium (Mg) based alloys have been extensively considered for their use as
biodegradable implant materials. However, controlling their corrosion rate in the …
biodegradable implant materials. However, controlling their corrosion rate in the …
[HTML][HTML] Recent research progress on magnesium alloys in Korea: A review
This review highlights the recent advancements in Mg research in South Korea with a prime
focus on high-speed-extrudable Mg–Bi-based alloys for high productivity and strength …
focus on high-speed-extrudable Mg–Bi-based alloys for high productivity and strength …
A Systematic Review and Network Meta‐Analysis of Biomedical Mg Alloy and Surface Coatings in Orthopedic Application
XY Lu, HX Cai, YR Li, X Zheng, J Yun… - Bioinorganic …, 2022 - Wiley Online Library
Magnesium alloys have great application prospects as ideal bone implant materials.
However, their poor corrosion resistance limits their clinical orthopedic application. Surface …
However, their poor corrosion resistance limits their clinical orthopedic application. Surface …
Emerging trends in the applications of metallic and ceramic biomaterials
S Desai, B Bidanda, PJ Bártolo - Bio-materials and prototyping …, 2021 - Springer
This chapter discusses the different types of biomaterials used for medical applications.
Metallic, ceramic, and nanomaterial-based biomaterials are classified and described based …
Metallic, ceramic, and nanomaterial-based biomaterials are classified and described based …
[HTML][HTML] Peri-implant tissue response and biodegradation performance of a Mg–1.0 Ca–0.5 Sr alloy in rat tibia
Biodegradable magnesium (Mg) alloys combine the advantages of traditional metallic
implants and biodegradable polymers, having high strength, low density, and a stiffness …
implants and biodegradable polymers, having high strength, low density, and a stiffness …
Direct writing of polymeric coatings on magnesium alloy for tracheal stent applications
This paper investigates the direct-write inkjet method for depositing multi-layer coatings of
biodegradable polymers on magnesium alloy surface. Immersion studies were conducted …
biodegradable polymers on magnesium alloy surface. Immersion studies were conducted …
Biocompatibility and efficiency of biodegradable magnesium-based plates and screws in the facial fracture model of beagles
BJ Kim, Y Piao, M Wufuer, WC Son, TH Choi - Journal of Oral and …, 2018 - Elsevier
Purpose A biodegradable magnesium alloy system has been developed as a substitute for
conventional plates and screws made of titanium or absorbable polymer. However, previous …
conventional plates and screws made of titanium or absorbable polymer. However, previous …
The formation of an organic coat and the release of corrosion microparticles from metallic magnesium implants
Magnesium alloys have been proposed as prospective degradable implant materials. To
elucidate the complex interactions between the corroding implants and the tissue …
elucidate the complex interactions between the corroding implants and the tissue …
Fatigue crack initiation change of cast AZ91 magnesium alloy from low to very high cycle fatigue region
Fatigue tests were performed on the AZ91 cast alloy to identify the mechanisms of the
fatigue crack initiation. In different fatigue regions, different mechanisms were observed. In …
fatigue crack initiation. In different fatigue regions, different mechanisms were observed. In …
Effects of gas produced by degradation of Mg–Zn–Zr Alloy on cancellous bone tissue
J Wang, H Jiang, Y Bi, J e Sun, M Chen… - Materials Science and …, 2015 - Elsevier
Abstract Mg–Zn–Zr alloy cylinders were implanted into the femoral condyles of Japanese big-
ear white rabbits. X-ray showed that by 12 weeks following implantation the implant became …
ear white rabbits. X-ray showed that by 12 weeks following implantation the implant became …