Cyclic testing of two-level control system using friction-yielding top plates in beam-to-column rigid connections

H Asgari, SM Zahrai, M Vajdian, SM Mirhosseini - Structures, 2024 - Elsevier
The use of two-level control systems in structures is one of those having attracted the
attention of researchers in the last decade. The design idea of the mentioned systems is to …

Research on the influence of panel zone on dynamic damage of multi-story steel structure

Z Xu, Y Zhao, H Wu, E Bao - European Journal of Environmental …, 2024 - Taylor & Francis
As the most important component of steel structure, the panel zone has done a lot of
research. In this article, the influence of the thickness of the panel zone on the performance …

[HTML][HTML] Experimental and Analytical Study on Non-Damaged Reinforcement Method for Pipe Rack Steel Structures

JS Lee, KJ Shin, JH Woo - Buildings, 2024 - mdpi.com
Pipe racks are steel structures that support various pipes transporting materials in industrial
complexes. The pipes on pipe racks may transport hazardous substances, which imposes …

Evaluating the Cyclic Behavior of the Sloped Extended End-plate Beam-to-column Connections

M Miryahyavi, R Khani, Y Hosseinzadeh - Periodica Polytechnica Civil …, 2023 - pp.bme.hu
Abstract In the Northridge and Kobe earthquakes, brittle failure of the welded beam-to-
column connections was observed in steel structures. So, bolted connections were …

Strength Evaluation of Flush End-Plate Connection Using Triangular Haunch in Pipe Rack

SH Kang, JS Lee, HI Park, HD Lee, KJ Shin - International Journal of Steel …, 2024 - Springer
In this paper, cyclic tests and finite element analyses were conducted on the flush end-plate
connection of a pipe rack, with the haunch shape attached to the bottom of a beam as a …

Investigating Effect of Friction-yielding Top Plate of Rigid Connections on Seismic Response of Special Moment Frames

H Asgari, SM Zahrai, M Vajdian, SM Mirhosseini - International Journal of …, 2024 - ije.ir
Acceptable seismic performance, ease and low cost in design and implementation are
advantages of passive dampers, but fixed performance parameters corresponding to the …

Retrofitting Bolted Flange Plate (BFP) Connections Using Haunches and Extended End-Plates

B Suswanto, F Ghifari, Y Tajunnisa… - Civil Engineering …, 2024 - civilejournal.org
In Indonesia, one of the most common forms of connection is the Bolted Flange Plate (BFP)
moment connection. Nevertheless, their current setups do not satisfy the strict requirements …

Strength Evaluation of Pipe‐Rack Connection Using Extended End Plate

SH Kang, JH Woo, KJ Shin, WG Lee, HI Park - ce/papers, 2023 - Wiley Online Library
Pipe‐rack structure is generally designed as a steel structure, but size of each column and
beam is small because vertical loads on the structure is relatively low. In addition, due to the …

بررسی عددی میراگر دوسطحی با ورق روسری در اتصال خمشی تیر به ستون

عسگری, هادی, زهرائی, وجدیان, میرحسینی - نشریه علمی و پژوهشی سازه و …, 2023‎ - journalisss.ir
زلزله‌های گذشته با تحمیل خسارت‌های زیاد، بیانگر ضعف عملکرد لرزه ‌ ای سازه‌ها به‌خصوص در محل
اتصال تیر به ستون بوده و کاربرد قطعاتی مثل میراگرهای اصطکاکی و جاری‌شونده جهت استهلاک …

[PDF][PDF] 파이프랙확장단부판접합부의내진성능에관한실험적연구

강성훈, 우종훈, 이희두, 이우근, 신경재 - 한국강구조학회논문집, 2022 - ksscjournal.or.kr
Pipe-rack structure is generally designed as a steel structure, but size of each column and
beam is small because vertical loads on the structure is relatively low. In addition, due to the …