A comparative study of traditional and contemporary building envelope construction techniques in terms of thermal comfort and energy efficiency in hot and humid …
P Lotfabadi, P Hançer - Sustainability, 2019 - mdpi.com
Expectations of traditional and contemporary buildings are different in terms of thermal
comfort. Traditional buildings mostly achieve comfort through passive means, without HVAC …
comfort. Traditional buildings mostly achieve comfort through passive means, without HVAC …
[HTML][HTML] Impact of low-income home energy-efficiency retrofits on building air tightness and healthy home indicators
We studied 226 low-income households as a part of the Colorado Home Energy Efficiency
and Respiratory Health (CHEER) study to investigate the relationship between energy …
and Respiratory Health (CHEER) study to investigate the relationship between energy …
Thermal and mechanical studies of perlite concrete casing for chimneys in residential buildings
K Drozdzol - Materials, 2021 - mdpi.com
Chimneys are structures designed to convey exhaust gases from heating devices to the
outside of buildings. The materials from which they are made have a great impact on their …
outside of buildings. The materials from which they are made have a great impact on their …
CFD thermal analysis of a three-layer chimney used in residential buildings
K Drozdzol - Journal of Building Engineering, 2021 - Elsevier
The two most important parameters to affect the performance and fire safety of a chimney are
its insulation properties and the temperature distribution across its layers. When designing a …
its insulation properties and the temperature distribution across its layers. When designing a …
Experimental study on the smouldering combustion of mineral wool insulation in chimney penetrations
P Leppänen, M Malaska - Fire technology, 2019 - Springer
A large number of fires have been caused by metal chimney penetrations in recent years.
One factor that has contributed to these occurrences is smouldering combustion within …
One factor that has contributed to these occurrences is smouldering combustion within …
Limiting the temperature at the chimney-roof penetration: innovative roof passage with fins and case to meet the latest European standards and enhance heat …
M Neri - Journal of Building Engineering, 2023 - Elsevier
To prevent overheating and consequent fires, European regulations prescribe thermal tests
to determine the distance between chimney and combustible materials. Traditional …
to determine the distance between chimney and combustible materials. Traditional …
Statistical approach to estimate the temperature in chimney roof penetration
M Neri, D Luscietti, A Fiorentino, M Pilotelli - Fire technology, 2018 - Springer
The paper shows how the Design of the Experiments can be used to determine
mathematical relations to estimate the maximum temperature reached by flammable …
mathematical relations to estimate the maximum temperature reached by flammable …
Comparison between European chimney test results and actual installations
P Leppänen, M Neri, D Luscietti, S Bani… - Journal of fire …, 2017 - journals.sagepub.com
European standards regulate the certification procedure for determining chimney class
temperature and the distance at which to install chimneys from combustible materials. These …
temperature and the distance at which to install chimneys from combustible materials. These …
Device for limiting the temperature at chimney-roof penetration in very critical chimney operating conditions
M Neri, M Pilotelli - Fire Technology, 2019 - Springer
In recent years, numerous roof fires have occurred due to the presence of a chimney, and
also certified chimneys were involved. Chimneys installers and chimney producers are …
also certified chimneys were involved. Chimneys installers and chimney producers are …
Fire safety study of a perlite concrete chimney and wooden ceilings used in buildings based on experimental tests and CFD analysis
K Drozdzol, M Kowalski… - Building Services …, 2024 - journals.sagepub.com
The operation of fuel-burning heating equipment results in soot build-up in the flues. Its
ignition poses a significant fire risk to the building, as the flue temperature can reach 1000° …
ignition poses a significant fire risk to the building, as the flue temperature can reach 1000° …