Imaging of temporal bone

I Pyykkö, J Zou, R Gürkov, S Naganawa… - Vestibular …, 2019 - karger.com
Multidetector computed tomography has been the benchmark for visualizing bony changes
of the ear, but has recently been challenged by cone-beam computed tomography. In both …

[HTML][HTML] Pre-, intra-and post-operative imaging of cochlear implants

TJ Vogl, A Tawfik, A Emam, NNN Naguib… - RöFo-Fortschritte auf …, 2015 - thieme-connect.com
The purpose of this review is to present essential imaging aspects in patients who are
candidates for a possible cochlear implant as well as in postsurgical follow-up. Imaging …

Comparison of a photon-counting-detector CT with an energy-integrating-detector CT for temporal bone imaging: a cadaveric study

W Zhou, JI Lane, ML Carlson… - American Journal …, 2018 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Evaluating abnormalities of the temporal bone requires
high-spatial-resolution CT imaging. Our aim was to assess the performance of photon …

Anatomo-radiological study of the superior semicircular canal dehiscence: radiological considerations of superior and posterior semicircular canals

M Crovetto, J Whyte, OM Rodriguez… - European journal of …, 2010 - Elsevier
INTRODUCTION: The main purpose of this study is to determine the radiological incidence
of Superior (SSCD) and Posterior Semicircular Canal Dehiscence (PSCD) and to compare …

[HTML][HTML] A comparative study of cranial, blunt trauma fractures as seen at medicolegal autopsy and by computed tomography

C Jacobsen, BH Bech, N Lynnerup - BMC medical imaging, 2009 - Springer
Abstract Background Computed Tomography (CT) has become a widely used supplement to
medico legal autopsies at several forensic institutes. Amongst other things, it has proven to …

Temporal bone CT: improved image quality and potential for decreased radiation dose using an ultra-high-resolution scan mode with an iterative reconstruction …

S Leng, FE Diehn, JI Lane, KK Koeller… - American Journal …, 2015 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Radiation dose in temporal bone CT imaging can be high
due to the requirement of high spatial resolution. In this study, we assessed whether CT …

HRCT and MRI findings in X-linked non-syndromic deafness patients with a POU3F4 mutation

WX Gong, RZ Gong, B Zhao - International journal of pediatric …, 2014 - Elsevier
Objective The aim of this study was to analyze HRCT and MRI findings in patients with X-
linked non-syndromic deafness and a POU3f4 mutation. Methods HRCT and MRI data of …

Two temporal bone computed tomography measurements increase recognition of malformations and predict sensorineural hearing loss

DD Purcell, NJ Fischbein, A Patel, J Johnson… - The …, 2006 - Wiley Online Library
Abstract Objectives/Hypothesis: The objectives of this prospective study were to assess the
reproducibility of the measurements of the cochlea and lateral semicircular canal (LSCC) …

Third window lesions

ML Ho - Neuroimaging Clinics, 2019 - neuroimaging.theclinics.com
Third window abnormalities are bony defects of the inner ear that enable abnormal
communication with the middle ear and/or cranial cavity. Normally, the inner ear and middle …

Spatial resolution improvement and dose reduction potential for inner ear CT imaging using az‐axis deconvolution technique

CH McCollough, S Leng, J Sunnegardh… - Medical …, 2013 - Wiley Online Library
Purpose: To assess the z‐axis resolution improvement and dose reduction potential
achieved using az‐axis deconvolution technique with iterative reconstruction (IR) relative to …