Numerical investigation of renal artery hemodynamics based on the physiological response to renal artery stenosis
M Andayesh, A Shahidian, M Ghassemi - Biocybernetics and Biomedical …, 2020 - Elsevier
Abstract Renal Artery Stenosis (RAS) is the narrowing of renal arteries, most often caused by
atherosclerosis or fibromuscular dysplasia. Possible complications of renal artery stenosis …
atherosclerosis or fibromuscular dysplasia. Possible complications of renal artery stenosis …
The Supera interwoven nitinol stent as a flow diverting device in popliteal aneurysms
L Van de Velde, E Groot Jebbink, BA Zambrano… - Cardiovascular and …, 2022 - Springer
Purpose The feasibility of using a compressed interwoven Supera stent as a flow diverting
device for popliteal aneurysms was recently demonstrated in patients. It is unclear, however …
device for popliteal aneurysms was recently demonstrated in patients. It is unclear, however …
Hemodynamic comparison of stent-grafts for the treatment of aortoiliac occlusive disease
A Chong, H Mirgolbabaee, Z Sun… - Journal of …, 2021 - journals.sagepub.com
Purpose: To compare the flow patterns and hemodynamics of the AFX stent-graft and the
covered endovascular reconstruction of aortic bifurcation (CERAB) configuration using laser …
covered endovascular reconstruction of aortic bifurcation (CERAB) configuration using laser …
Validation of ultrasound velocimetry and computational fluid dynamics for flow assessment in femoral artery stenotic disease
L van de Velde, M van Helvert… - Journal of Medical …, 2024 - spiedigitallibrary.org
Purpose To investigate the accuracy of high-framerate echo particle image velocimetry
(ePIV) and computational fluid dynamics (CFD) for determining velocity vectors in femoral …
(ePIV) and computational fluid dynamics (CFD) for determining velocity vectors in femoral …
Experimental Analysis of Pressure and Flow Alterations During and After Insertion of a Multilayer Flow Modulator into an AAA Model with Incorporated Branch
Purpose The multilayer flow modulator (MFM) device has been used for the treatment of
abdominal aortic aneurysm (AAA) for over a decade. Although several clinical studies have …
abdominal aortic aneurysm (AAA) for over a decade. Although several clinical studies have …
Renal artery coverage during endovascular aneurysm repair for ruptured abdominal aortic aneurysm
Introduction Coverage of one or both renal arteries may be required to facilitate
endovascular aneurysm repair (EVAR) in patients who are not candidates for open surgery …
endovascular aneurysm repair (EVAR) in patients who are not candidates for open surgery …
In-vitro particle image velocimetry assessment of the endovascular haemodynamic features distal of stent-grafts that are associated with development of limb …
SG Yazdi, PD Docherty, A Khanafer… - Journal of the Royal …, 2021 - Taylor & Francis
Aneurysms are common vascular diseases which affect normal haemodynamics in the
aorta. Endovascular aortic repair (EVAR) using stent-grafts is a common treatment that …
aorta. Endovascular aortic repair (EVAR) using stent-grafts is a common treatment that …
[HTML][HTML] Haemodynamics in different flow lumen configurations of customised aortic repair for infrarenal aortic aneurysms
SP Overeem, JPPM de Vries, JT Boersen… - European Journal of …, 2019 - Elsevier
Objective Customised aortic repair (CAR) is a new and minimally invasive technique for the
endovascular treatment of abdominal aortic aneurysms (AAAs). The aneurysm is completely …
endovascular treatment of abdominal aortic aneurysms (AAAs). The aneurysm is completely …
In Vitro Radiological Evaluation of Different Types of Chimney Stents Using a Silicon Flow Model with Adjustable Physiological Simulating Conditions
GT Taneva, MV Usai, GA Pitoulias, KP Donas - European Journal of …, 2023 - Elsevier
Objective To evaluate in vitro the performance of in vivo published covered or bare metal
chimney stents (ChSs) in combination with the Endurant II abdominal endograft (Medtronic) …
chimney stents (ChSs) in combination with the Endurant II abdominal endograft (Medtronic) …
[HTML][HTML] Hemodynamics in renal arteries with partial coverage after endovascular aneurysm repair affected by renal orientations
J Wen, X Liu, J Lei, J Wang, X Chen, T Zheng… - Medicine in Novel …, 2023 - Elsevier
Endovascular aortic repair (EVAR) has been increasingly used to treat abdominal aortic
aneurysm (AAA) due to its lower mortality and shorter recovery time. However, the …
aneurysm (AAA) due to its lower mortality and shorter recovery time. However, the …