[HTML][HTML] Prosthetic hip-associated cobalt toxicity: a systematic review of case series and case reports
JRW Crutsen, MC Koper, J Jelsma… - EFORT Open …, 2022 - eor.bioscientifica.com
Prosthetic hip-associated cobalt toxicity (PHACT) is caused by elevated blood cobalt
concentrations after hip arthroplasty. The aim of this study is to determine which symptoms …
concentrations after hip arthroplasty. The aim of this study is to determine which symptoms …
Surgical management of hip prosthetic failure in metallosis: A case series and literature review
F Pisanu, M Andreozzi, E Fiori, F Altamore… - Journal of …, 2021 - Elsevier
Local and remote complications can be observed in hip prosthesis failures associated with
metallosis. Structural changes in the periprosthetic bone and soft tissues may not always be …
metallosis. Structural changes in the periprosthetic bone and soft tissues may not always be …
Are serum cobalt and chromium levels predictors for patient-reported outcome measures in the ASR hip resurfacing arthroplasty?: insights from a ten-year prospective …
MC Koper, RWA Spek, M Reijman… - The Bone & Joint …, 2023 - boneandjoint.org.uk
Aims The aims of this study were to determine if an increasing serum cobalt (Co) and/or
chromium (Cr) concentration is correlated with a decreasing Harris Hip Score (HHS) and Hip …
chromium (Cr) concentration is correlated with a decreasing Harris Hip Score (HHS) and Hip …
Development, validation and application of an inductively coupled plasma–mass spectrometry method to determine cobalt in metal-on-metal prosthesis patients using …
S Capiau, E Bolea-Fernandez, L Balcaen… - Talanta, 2020 - Elsevier
Abstract Metal-on-metal (MoM) prostheses, in which the bearing surfaces are made of a
metal alloy, may release metal ions upon wear and corrosion, potentially inducing both local …
metal alloy, may release metal ions upon wear and corrosion, potentially inducing both local …
Revision total hip arthroplasty for metal-on-metal failure
JS Chang, FS Haddad - Journal of Clinical Orthopaedics and Trauma, 2020 - Elsevier
Abstract Metal-on-metal (MoM) arthroplasty systems became popular in the early-2000s due
to presumed advantages of improved wear characteristics and superior stability. However …
to presumed advantages of improved wear characteristics and superior stability. However …
[HTML][HTML] A rare case of adverse reaction to metal debris in a ceramic-on-ceramic total hip replacement
A Cannella, T Greco, C Polichetti, I De Martino… - Journal of Functional …, 2022 - mdpi.com
Adverse Reaction to Metal Debris (ARMD) is one of the most frequent complications after
Total Hip Replacement (THR) and often a cause of surgical revision. This is true especially …
Total Hip Replacement (THR) and often a cause of surgical revision. This is true especially …
Metal-on-metal total hip revisions: Pearls and pitfalls
JI Law, DA Crawford, JB Adams… - The Journal of …, 2020 - Elsevier
Background At the turn of the 21st century, there was a re-emergence of metal-on-metal
(MoM) articulation with 35% of all total hip arthroplasty implants having MoM articulation …
(MoM) articulation with 35% of all total hip arthroplasty implants having MoM articulation …
[HTML][HTML] No threshold exists for recommending revision surgery in metal-on-metal hip arthroplasty patients with adverse reactions to metal debris: a retrospective …
GS Matharu, F Berryman, DJ Dunlop, MP Revell… - The Journal of …, 2019 - Elsevier
Background Surgeons currently have difficulty when managing metal-on-metal hip
arthroplasty (MoMHA) patients with adverse reactions to metal debris (ARMD). This stems …
arthroplasty (MoMHA) patients with adverse reactions to metal debris (ARMD). This stems …
[HTML][HTML] Long-Term Outcome of Metal-on-Metal Total Hip Arthroplasty with Modular Neck Stem
H Wakabayashi, M Hasegawa, Y Naito, S Tone… - Journal of Clinical …, 2024 - mdpi.com
Background: This study aimed to report the long-term outcomes of total hip arthroplasty
(THA) using a Conserve Plus (Wright Medical, Japan) metal-on-metal (MoM) acetabular …
(THA) using a Conserve Plus (Wright Medical, Japan) metal-on-metal (MoM) acetabular …
Outcome of revised metal-on-metal hip arthroplasties: a Dutch arthroplasty register study
J Jelsma, SMJ Van Kuijk… - Archives of Orthopaedic …, 2022 - Springer
Background Preliminary results of metal-on-metal (MoM) hip arthroplasty were satisfactory,
but since 2004 data showed high failure rates. National joint replacement registries are multi …