Thermodynamic analyses and performance improvement on a novel cascade-coupling-heating heat pump system for high efficiency hot water production

Y Xu, J Wang, X Shen, Z Sun, X Wang, X Han - Energy Conversion and …, 2023 - Elsevier
In the background of global warming and reducing carbon emission, air-source heat pump
water heater is used as an energy efficient technology to improve the efficiency of building …

Life cycle performance evaluation of cascade-heating high temperature heat pump system for waste heat utilization: Energy consumption, emissions and financial …

B Dai, X Liu, S Liu, D Wang, C Meng, Q Wang, Y Song… - Energy, 2022 - Elsevier
Inspired by the principle of cascade energy utilization, the concept of cascade-heating is
introduced, and five layouts of cascade-heating high temperature heat pump (HTHP) …

A newly designed air-source heat pump system with liquid subcooling defrosting: Simulation and experiment

J Niu, Z Liang, T Lv, H Wang, S Xu - Applied Thermal Engineering, 2024 - Elsevier
A new type of air-source heat pump system with liquid subcooling defrosting (ASHPSD) was
proposed, in which a hot liquid refrigerant is used for defrosting; further, the outdoor unit of …

Experimental investigation of heating performance of air source heat pump with stable heating capacity during defrosting

C Liang, X Li, X Meng, W Shi, J Gu, B Wang… - Applied Thermal …, 2023 - Elsevier
Traditional air source heat pumps with reverse defrosting and hot gas bypass defrosting
methods significantly decrease the heating capacity and even extract heat from the user …

[HTML][HTML] New zeotropic CO2-based refrigerant mixtures for cascade high-temperature heat pump to reach heat sink temperature up to 180° C

P Ganesan, TM Eikevik - Energy Conversion and Management: X, 2023 - Elsevier
There is a great demand for clean, high-temperature heating in industries. The present work
demonstrates the modeling and analysis of a high-temperature heat pump (HTHP) using a …

[HTML][HTML] Thermodynamic evaluation of CO2 for ultra-low temperature refrigeration

CM Udroiu, A Mota-Babiloni, P Giménez-Prades… - Energy Conversion and …, 2023 - Elsevier
Abstract Carbon dioxide (CO 2, R744) is the only refrigerant in the safest class by the
ASHRAE 34 Standard in the group of natural refrigerants, with zero ozone depletion …

A data-driven evaluating method on the defrosting effect of the air source heat pump system in Beijing

Y Guo, S Shao, X Geng, H Li, Z Wang… - Applied Thermal …, 2023 - Elsevier
The current demand-based defrosting initiation strategies of air source heat pumps (ASHPs)
faces difficulty in achieving a balance between cost and robustness. Therefore, an efficient …

Experimental and theoretical assessments on the systematic performance of a single-stage air-source heat pump using ternary mixture in cold regions

J Luo, K Yang, Y Liu, Z Zhao, G Chen… - Applied Thermal …, 2023 - Elsevier
The performance of air-source heat pump is strongly influenced by ambient temperature
variation. Improving its stability and efficiency during wintertime is important for promoting its …

Performance evaluation of a novel mixed-refrigerant recuperative heat pump with a large temperature lift for space heating

S Sun, Z Liu, Y Sun, H Guo, M Gong - Applied Thermal Engineering, 2023 - Elsevier
The conventional techniques for space heating consume great energy and cause great CO
2 emissions, which is not meet the requirement of sustainable development. Heat pumps are …

Distributed multienergy and low-carbon heating technology for rural areas in northern China

H Qi, J Zhou, T Ren, S Sun, Z He, Z Sun, S Dong… - Energy, 2024 - Elsevier
In the context of China's “double carbon” policy and “rural revitalization” strategy, clean and