An advanced unmanned aerial vehicle (UAV) approach via learning-based control for overhead power line monitoring: A comprehensive review
Detection and prevention of faults in overhead electric lines is critical for the reliability and
availability of electricity supply. The disadvantages of conventional methods range from …
availability of electricity supply. The disadvantages of conventional methods range from …
Measurement and modelling of leakage current behaviour in ZnO surge arresters under various applied voltage amplitudes and pollution conditions
In zinc oxide (ZnO) surge arresters, leakage current usually flows across the arrester under
normal operating condition. Leakage current is one of the factors which contribute towards …
normal operating condition. Leakage current is one of the factors which contribute towards …
Analysis of thermal effects for polymer-housed metal-oxide surge arrester under multiple strokes
L Huang, L Zhou, W Chen, R Wei… - … on Power Delivery, 2022 - ieeexplore.ieee.org
Multiple strokes are the main factors affecting the safe and stable operation of power
equipment. As the core lightning protection equipment, arresters are also frequently …
equipment. As the core lightning protection equipment, arresters are also frequently …
The failure arc paths of the novel device combining an arrester and an insulator under different pollution levels
X Qiao, Z Zhang, R Sundararajan, X Jiang, J Hu… - International Journal of …, 2021 - Elsevier
Lightning strokes on transmission lines could trigger insulation failure if no protective
measures are taken. Typically, a lightning arrester is used for this purpose. In order to …
measures are taken. Typically, a lightning arrester is used for this purpose. In order to …
Performance evaluation of distribution and low-voltage networks under direct lightning flashes with paralleled triac-surge arrester
NA Sabiha, HI Alkhammash - Electric Power Systems Research, 2023 - Elsevier
The service continuity of the distribution electrical network faces challenges. Among these
challenges is the provision of protection against surge arrester failure, in which it is …
challenges is the provision of protection against surge arrester failure, in which it is …
Failure risk assessment of surge arrester using paralleled spark gap
NA Sabiha, F Mahmood, AM Abd-Elhady - IEEE Access, 2020 - ieeexplore.ieee.org
Surge arresters are usually used to protect distribution feeders against randomly distributed
lightning overvoltages. However, there is a probability of surge arrester failure due to an …
lightning overvoltages. However, there is a probability of surge arrester failure due to an …
Estimation of energy stress of surge arresters considering the high-frequency behavior of grounding systems
R Shariatinasab, J Gholinezhad… - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
This paper presents a probabilistic evaluation of energy absorption capability of
transmission line surge arresters (SAs), based on Monte-Carlo method. In the presented …
transmission line surge arresters (SAs), based on Monte-Carlo method. In the presented …
Limiting surge arrester failure under direct lightning strokes for attaining service continuity of distribution networks
NA Sabiha - IET Generation, Transmission & Distribution, 2020 - Wiley Online Library
This study introduces an arrangement of surge arrester, Rogowski coil, and triac to attain
service continuity of distribution networks. This new arrangement is proposed to limit the …
service continuity of distribution networks. This new arrangement is proposed to limit the …
Energy stress of non-gapped line arresters due to lightning strikes to a 150 kV line: Concentrated tower grounding system modeling effects
This study investigates the impact of the frequency-and current-dependent behavior of
concentrated tower grounding systems on the computed fast-front overvoltages across …
concentrated tower grounding systems on the computed fast-front overvoltages across …
Tower grounding improvement versus line surge arresters: Comparison of remedial measures for high-BFOR subtransmission lines
This paper presents a technical/economic comparison between remedial measures aimed
at improving the lightning performance of an existing Italian three-phase 150-kV overhead …
at improving the lightning performance of an existing Italian three-phase 150-kV overhead …