An advanced unmanned aerial vehicle (UAV) approach via learning-based control for overhead power line monitoring: A comprehensive review

HA Foudeh, PCK Luk, JF Whidborne - IEEE Access, 2021 - ieeexplore.ieee.org
Detection and prevention of faults in overhead electric lines is critical for the reliability and
availability of electricity supply. The disadvantages of conventional methods range from …

Measurement and modelling of leakage current behaviour in ZnO surge arresters under various applied voltage amplitudes and pollution conditions

NAA Latiff, HA Illias, AHA Bakar, SZA Dabbak - Energies, 2018 - mdpi.com
In zinc oxide (ZnO) surge arresters, leakage current usually flows across the arrester under
normal operating condition. Leakage current is one of the factors which contribute towards …

Analysis of thermal effects for polymer-housed metal-oxide surge arrester under multiple strokes

L Huang, L Zhou, W Chen, R Wei… - … on Power Delivery, 2022 - ieeexplore.ieee.org
Multiple strokes are the main factors affecting the safe and stable operation of power
equipment. As the core lightning protection equipment, arresters are also frequently …

The failure arc paths of the novel device combining an arrester and an insulator under different pollution levels

X Qiao, Z Zhang, R Sundararajan, X Jiang, J Hu… - International Journal of …, 2021 - Elsevier
Lightning strokes on transmission lines could trigger insulation failure if no protective
measures are taken. Typically, a lightning arrester is used for this purpose. In order to …

Performance evaluation of distribution and low-voltage networks under direct lightning flashes with paralleled triac-surge arrester

NA Sabiha, HI Alkhammash - Electric Power Systems Research, 2023 - Elsevier
The service continuity of the distribution electrical network faces challenges. Among these
challenges is the provision of protection against surge arrester failure, in which it is …

Failure risk assessment of surge arrester using paralleled spark gap

NA Sabiha, F Mahmood, AM Abd-Elhady - IEEE Access, 2020 - ieeexplore.ieee.org
Surge arresters are usually used to protect distribution feeders against randomly distributed
lightning overvoltages. However, there is a probability of surge arrester failure due to an …

Estimation of energy stress of surge arresters considering the high-frequency behavior of grounding systems

R Shariatinasab, J Gholinezhad… - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
This paper presents a probabilistic evaluation of energy absorption capability of
transmission line surge arresters (SAs), based on Monte-Carlo method. In the presented …

Limiting surge arrester failure under direct lightning strokes for attaining service continuity of distribution networks

NA Sabiha - IET Generation, Transmission & Distribution, 2020 - Wiley Online Library
This study introduces an arrangement of surge arrester, Rogowski coil, and triac to attain
service continuity of distribution networks. This new arrangement is proposed to limit the …

Energy stress of non-gapped line arresters due to lightning strikes to a 150 kV line: Concentrated tower grounding system modeling effects

ZG Datsios, DG Patsalis, E Stracqualursi… - … on Environment and …, 2024 - ieeexplore.ieee.org
This study investigates the impact of the frequency-and current-dependent behavior of
concentrated tower grounding systems on the computed fast-front overvoltages across …

Tower grounding improvement versus line surge arresters: Comparison of remedial measures for high-BFOR subtransmission lines

FM Gatta, A Geri, S Lauria, M Maccioni… - IEEE Transactions on …, 2015 - ieeexplore.ieee.org
This paper presents a technical/economic comparison between remedial measures aimed
at improving the lightning performance of an existing Italian three-phase 150-kV overhead …