Second-order level-crossing sampling analog to digital converter for electrocardiogram delineation and premature ventricular contraction detection
X Tang, M Renteria-Pinon… - IEEE Transactions on …, 2023 - ieeexplore.ieee.org
This article presents an electrocardiogram (ECG) delineation and arrhythmia heartbeat
detection system using a novel second-order level-crossing sampling analog to digital …
detection system using a novel second-order level-crossing sampling analog to digital …
Wearable Sensors for Vital Signs: A Review of 20 Years in BioCAS and Future Directions
Y Suo, Y Zhao, Y Lian - 2024 IEEE Biomedical Circuits and …, 2024 - ieeexplore.ieee.org
This paper presents a comprehensive review of the advancements of wearables over 20
years of BioCAS and explores future directions in the field. The review focuses on the …
years of BioCAS and explores future directions in the field. The review focuses on the …
A 36-nW Electrocardiogram Anomaly Detector based on a 1.5-bit Non-Feedback Delta Quantizer for Always-on Cardiac Monitoring
N Pu, N Wu, SM Abubakar, Y Yang… - … Circuits and Systems, 2024 - ieeexplore.ieee.org
An always-on electrocardiogram (ECG) anomaly detector (EAD) with ultra-low power (ULP)
consumption is proposed for continuous cardiac monitoring applications. The detector is …
consumption is proposed for continuous cardiac monitoring applications. The detector is …
A Low-Power Co-Processor to Predict Ventricular Arrhythmia for Wearable Healthcare Devices
M Janveja, R Parmar, S Dash… - IEEE Transactions on …, 2024 - ieeexplore.ieee.org
Ventricular arrhythmia (VA) is the most critical cardiac anomaly among all arrhythmia beats.
Thus, it becomes imperative to predict the occurrence of VA to avoid sudden casualties …
Thus, it becomes imperative to predict the occurrence of VA to avoid sudden casualties …
A 12-Lead ECG Delineation Algorithm based on a Quantized CNN-BiLSTM Auto-encoder with 1-12 Mapping
12-lead electrocardiogram (ECG) delineation is a critical step in diagnosing of various heart
diseases. Current practices for 12-lead ECG delineation typically involve processing each of …
diseases. Current practices for 12-lead ECG delineation typically involve processing each of …
Second-Order Level-Crossing Sampling Analog to Digital Converter for Data Savings in Real-Time Sparse Signal Sensing
M Renteria-Pinon - 2023 - search.proquest.com
This work presents a real-time sparse signal sensing system using a fully integrated second-
order level-crossing sampling analog-to-digital converter (ADC) for data compression and …
order level-crossing sampling analog-to-digital converter (ADC) for data compression and …
A Peak Detection Algorithm for Multimodal Physiological Signals Based on U-Net
H Wang, X Xu, Q Cai, R Sun, H Wu… - … Circuits and Systems …, 2023 - ieeexplore.ieee.org
Fiducial points detection serves as the cornerstone of physiological signal processing.
Conventional multimodal biomedical sensors require the deployment of diverse or …
Conventional multimodal biomedical sensors require the deployment of diverse or …
Wearable Sensors for Vital Signs: A Review of 20 Years and Future Directions
Y Suo, H Guo, R Yu, Y Zhao - Integrated Circuits and Systems, 2024 - ieeexplore.ieee.org
This paper presents a comprehensive review of the advancements of wearables over 20
years and explores future directions in the field. The review focuses on the evolving needs …
years and explores future directions in the field. The review focuses on the evolving needs …
A 1.83 μ J High-Robust Cardiac Health Monitoring with Adaptive-Threshold QRS Detector and Hybrid Neural Network Arrhythmia Classifier
G Wei, G Deng, X Lu, B Li - 2024 IEEE Biomedical Circuits and …, 2024 - ieeexplore.ieee.org
Arrhythmia is a crucial method for monitoring cardiac health. However, Electrocardiogram
(ECG) signals obtained from wearable devices are often contaminated by noise (such as …
(ECG) signals obtained from wearable devices are often contaminated by noise (such as …
A Multi-Channel 133-dB DR PPG/ECG SoC for Smart Wearable Devices
S Zhou, X Wang, Y Suo, X Han… - Integrated Circuits and …, 2024 - ieeexplore.ieee.org
Real-time monitoring of multimodal vital signs including electrocardiography (ECG) and
photoplethysmography (PPG) on wearable devices are attracting increasing interests …
photoplethysmography (PPG) on wearable devices are attracting increasing interests …