Contact lens sensors in ocular diagnostics

NM Farandos, AK Yetisen, MJ Monteiro… - Advanced …, 2015 - Wiley Online Library
Contact lenses as a minimally invasive platform for diagnostics and drug delivery have
emerged in recent years. Contact lens sensors have been developed for analyzing the …

Wearable and implantable intraocular pressure biosensors: recent progress and future prospects

C Yang, X Huang, X Li, C Yang, T Zhang… - Advanced …, 2021 - Wiley Online Library
Biosensors worn on or implanted in eyes have been garnering substantial attention since
being proven to be an effective means to acquire critical biomarkers for monitoring the states …

Recent progress of continuous intraocular pressure monitoring

J Xu, R Li, H Xu, Y Yang, S Zhang, TL Ren - Nano Select, 2022 - Wiley Online Library
Glaucoma, a chronic optic neuropathy, is the leading cause of irreversible blindness in the
world. Elevated intraocular pressure (IOP) has been considered to be the major contributor …

Assessment of intraocular pressure sensing using an implanted reflective flexible membrane

A Nazarov, B Knyazer, T Lifshitz… - Journal of …, 2017 - spiedigitallibrary.org
Glaucoma is a neurodegenerative condition that is the leading cause of irreversible
blindness worldwide. Elevated intraocular pressure (IOP) is the main cause for the …

A wireless photonic intraocular pressure sensor

M Manzo, O Cavazos - … Engineering Congress and …, 2017 - asmedigitalcollection.asme.org
In this paper, we propose analytical and numerical experiments to investigate the feasibility
of a wireless photonic sensor for measuring the intraocular pressure (IOP). The sensing …

Hermetic capacitive pressure sensors for biomedical applications

D Diaz-Alonso, M Moreno-Moreno, C Zuñiga… - Microelectronics …, 2016 - emerald.com
Purpose This paper aims to purpose the new design and fabrication scheme of Touch Mode
Capacitive Pressure Sensor (TMCPS), which can be used in a wireless integrated resistor …

眼壓光學傳感器的改良與其光學特性的模擬

H Wei-Chung - 臺灣大學光電工程學研究所學位論文, 2016 - airitilibrary.com
Monitoring intraocular pressure (IOP) has been known as an important diagnostic procedure
to treat glaucoma patients; therefore, to have a convenient monitoring tool is essential …

A readout circuit for wireless passive resonant-circuit sensors

K Bao, D Chen, Q Shi, J Chen, J Wang - SENSORS, 2013 IEEE, 2013 - ieeexplore.ieee.org
This paper presents a readout circuit for wireless passive LC sensors, where the phase of
the readout coil shows a small" dip" nearby the sensor's resonant frequency in the low …

Efficient objective metric tool for medical electrical device development: Eye phantom for glaucoma diagnosis device

A Deluthault, L Mezenge, P Cauvet… - Journal of …, 2017 - Wiley Online Library
Developing electronic medical devices is challenging. Simulations or in vivo experiments
are not sufficient to obtain pertinent comparisons between potential design options. This …

Solutions for the self-adaptation of communicating systems in operation

M Andraud, A Deluthault, M Dieng… - 2014 IEEE 20th …, 2014 - ieeexplore.ieee.org
In the context of mission-critical, safety-critical, and remote-controlled applications, it is
required to equip systems with self-adapting capabilities. Adaptation is required in post …