Space-resolved extreme ultraviolet spectrometer for impurity emission profile measurement in large helical device

C Dong, S Morita, M Goto, H Zhou - Review of Scientific Instruments, 2010 - pubs.aip.org
A space-resolved extreme ultraviolet (EUV) spectrometer working in 60–400 Å range has
been developed to observe impurity emission profiles in core and edge plasmas of Large …

Measurements of visible bremsstrahlung and automatic Bayesian inference of the effective plasma charge Zeff at W7-X

A Pavone, U Hergenhahn, M Krychowiak… - Journal of …, 2019 - iopscience.iop.org
The effective charge Z eff indicates the overall impurity contamination of a plasma. Z eff can
be derived experimentally from the intensity of the plasma bremsstrahlung emission. We …

Absolute intensity calibration of flat-field space-resolved extreme ultraviolet spectrometer using radial profiles of visible and extreme ultraviolet bremsstrahlung …

C Dong, S Morita, M Goto, E Wang - Review of Scientific Instruments, 2011 - pubs.aip.org
A precise absolute intensity calibration of a flat-field space-resolved extreme ultraviolet
(EUV) spectrometer working in wavelength range of 60–400 Å is carried out using a new …

Experimental study of impurity screening in the edge ergodic layer of the large helical device using carbon emissions of CIII to CVI

MB Chowdhuri, S Morita, M Kobayashi, M Goto… - Physics of …, 2009 - pubs.aip.org
Four resonance transitions of CIII (977.03 Å: 2 s 2 S 1 0-2 s 2 p P 1 1)⁠, CIV (1550 Å: 2 s S 2-
2 p P 2)⁠, CV (40.27 Å: 1 s 2 S 1 0-1 s 2 p P 1 1)⁠, and CVI (33.73 Å: 1 s S 2-2 p P 2) have …

Space-resolved extreme ultraviolet spectroscopy free of high-energy neutral particle noise in wavelength range of 10–130 Å on the large helical device

X Huang, S Morita, T Oishi, M Goto… - Review of Scientific …, 2014 - pubs.aip.org
A flat-field space-resolved extreme ultraviolet (EUV) spectrometer system working in
wavelength range of 10–130 Å has been constructed in the Large Helical Device (LHD) for …

Performance improvement of two-dimensional EUV spectroscopy based on high-frame-rate CCD and signal normalization method in Large Helical Device

H Zhang, S Morita, T Oishi, M Goto… - Japanese Journal of …, 2015 - iopscience.iop.org
Abstract In the Large Helical Device (LHD), two-dimensional (2D) distribution of edge
impurity line emissions from the ergodic layer with a three-dimensional (3D) magnetic field …

Effective ion charge (Zeff) measurements and impurity behavior in KSTAR

S Sarwar, HK Na, JM Park - Review of Scientific Instruments, 2018 - pubs.aip.org
A visible bremsstrahlung detector array diagnostic system has been developed on the Korea
Superconducting Tokamak Advanced Research (KSTAR) to view the whole minor radius in …

Zeff profile diagnostics using visible bremsstrahlung continuum for nonaxisymmetric plasmas with finite β in large helical device

HY Zhou, S Morita, M Goto, CF Dong - Journal of Applied Physics, 2010 - pubs.aip.org
An astigmatism-corrected Czerny–Turner-type visible spectrometer coupled with a charge-
coupled device has been installed in large helical device (LHD) to measure visible …

Passive Spectroscopy in Visible, VUV, and X-Ray Ranges for LHD Diagnostics

M Goto, S Morita, HY Zhou, CF Dong… - Fusion Science and …, 2010 - Taylor & Francis
Various types of spectrometers corresponding to different wavelength ranges from X-ray to
visible have been developed for the Large Helical Device (LHD). The charge-coupled …

Miniaturization of optical spectroscopes into Fresnel microspectrometers

Y Park, SH Choi - Journal of Nanophotonics, 2013 - spiedigitallibrary.org
Miniaturized optical instruments have become very important in industry as smart phones
and tablet PCs increase in popularity. A chronology of spectrometer development shows that …