[PDF][PDF] Observation of burst frequency in extracted ECR ion current
GS Taki, PR Sarma, AG Drentje, T Nakagawa… - 高能物理与核 …, 2007 - academia.edu
Earlier we reported an ion current jump which was observed at a fixed negative biased disc
potential in the 6.4 GHz ECR ion source at VECC, Kolkata. In a recent experiment with neon …
potential in the 6.4 GHz ECR ion source at VECC, Kolkata. In a recent experiment with neon …
6.4 GHz ECR ion source at VECC
GS Taki, DK Chakraborty, RK Bhandari - Pramana, 2002 - Springer
The 6.4 GHz ECR ion source that was indigenously developed a few years ago has been
operating continuously for injecting oxygen and neon beams to the cyclotron since 1997 …
operating continuously for injecting oxygen and neon beams to the cyclotron since 1997 …
Abrupt variation in ion current with biased disk voltage in the electron cyclotron resonance ion source
GS Taki, PR Sarma, DK Chakraborty… - Review of scientific …, 2006 - pubs.aip.org
The performance of the biased disk in the 6.4 GHz electron cyclotron resonance ion source
at VECC, Kolkata was studied at a pressure of∼ 1× 10− 7 Torr. We observed an abrupt …
at VECC, Kolkata was studied at a pressure of∼ 1× 10− 7 Torr. We observed an abrupt …
A study on vacuum aspects of electron cyclotron resonance ion source plasma
S Ghosh, GS Taki, C Mallick… - Journal of Physics …, 2008 - iopscience.iop.org
The electron cyclotron resonance (ECR) ion source is special type hot plasma machine
where the high temperature electrons co-exist with multiply charge state ions and neutrals. A …
where the high temperature electrons co-exist with multiply charge state ions and neutrals. A …
[PDF][PDF] Performance of a 6.4 GHz ECR ion source at VECC
GS Taki, DK Chakraborty, PS Chakraborty… - … and Abstract of the …, 2001 - conference.kek.jp
Abstract The 6.4 GHz Electron Cyclotron Resonance Ion Source has been put into
continuous operation for injecting remarkably stable oxygen and neon beams to the …
continuous operation for injecting remarkably stable oxygen and neon beams to the …
Effect of biasing electrode on ECR beam current
GS Taki, PR Sarma, DK Chakraborty, RK Bhandari… - 2005 - osti.gov
The beam current in ECR ion sources can be enhanced by inserting a biasing electrode
near the ECR region on the injection side. We have experimentally studied the variation of …
near the ECR region on the injection side. We have experimentally studied the variation of …
6.4 GHz electron cyclotron resonance ion source at VECC, Kolkata
GS Taki, DK Chakraborty, RK Bhandari - DAE-BRNS Indian particle …, 2005 - inis.iaea.org
[en] The first indigenous Electron Cyclotron Resonance (ECR) Ion Source was developed in
VECC in 1991 for injecting heavy ions into VEC to facilitate heavy ion acceleration …
VECC in 1991 for injecting heavy ions into VEC to facilitate heavy ion acceleration …
Role of vacuum in electron cyclotron resonance ion source plasma
Vacuum plays a major rule in Electron Cyclotron Resonance Ion Source (ECRIS). ECRIS
plasma discharge takes place in vacuum of the order of 10 {sup-7} Torr. The low-pressure …
plasma discharge takes place in vacuum of the order of 10 {sup-7} Torr. The low-pressure …