Probabilistic framework for vulnerability analysis of coupling capacitor voltage transformer to ferroresonance phenomenon

M Tajdinian, M Allahbakhshi, B Behdani… - IET Science …, 2020 - Wiley Online Library
The performance of measurement transformers especially in transient phenomena affects
the monitoring, control and protective devices. Coupling capacitor voltage transformer …

A new control unit for electronic ferroresonance suppression circuit in capacitor voltage transformers

M Navaei, AA Abdoos, M Shahabi - … Journal of Electrical Power & Energy …, 2018 - Elsevier
Ferroresonance suppression circuit (FSC) as an important portion of capacitor voltage
transformer (CVT) has a vital role in the prevention of overvoltages. There are three types of …

Tuning CCVT frequency response data for improvement of numerical distance protection

EP Machado, D Fernandes… - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
A new method to numerically estimate the primary voltage waveform of coupling capacitor
voltage transformers is presented. The outcome is a simple digital filter suitable for the …

A positive-sequence current based directional relaying approach for CCVT subsidence transient condition

M Biswal, S Biswal - Protection and Control of Modern Power …, 2017 - ieeexplore.ieee.org
In this work, a directional relaying algorithm is proposed for transmission line to prevent
relay maloperation during coupling capacitor voltage transformer (CCVT) subsidence …

Study of the impact of switching transient overvoltages on ferroresonance of CCVT in series and shunt compensated power systems

M Tajdinian, M Allahbakhshi, S Biswal… - IEEE Transactions …, 2019 - ieeexplore.ieee.org
Ferroresonance phenomenon (FP) in a coupling capacitor voltage transformer (CCVT)
profoundly deforms the voltage waveform. Transient overvoltage due to transmission line …

Auxiliary Prony‐based algorithm for performance improvement of DFT phasor estimator against transient of CCVT

M Tajdinian, M Allahbakhshi, AR Seifi… - IET Science …, 2019 - Wiley Online Library
The measured fault voltage signal through coupling capacitor voltage transformer (CCVT)
contains transient components which highly affect the estimated fundamental frequency …

Power systems frequency estimation using amplitude tracking square wave for low-end protective relays

A Ukil, YM Yeap, K Satpathi - Measurement, 2019 - Elsevier
Growing emphasis on the disturbance-free electrical power distribution demands for
economical and efficient smart estimation techniques in the automation architectures of the …

An adaptive algorithm to prevent distance relay overreach during CCVT transient

S Biswal, M Biswal, AY Abdelaziz - Electric Power Systems Research, 2018 - Elsevier
In this paper, the impact of coupling capacitor voltage transformer (CCVT) subsidence
transients on the performance of distance relay is investigated. The reach accuracy of …

Electronic resistor emulators for ferroresonance damping in MV transformers

E Bayona, F Azcondo, C Brañas, J Diaz… - IET Renewable …, 2019 - Wiley Online Library
The occurrence of ferroresonances, due to the presence of voltage transformers in isolated‐
neutral in medium‐voltage (MV) distribution grids, results in overvoltages and overcurrents …

Ferroresonance phenomena in medium‐voltage isolated neutral grids: a case study

R Martínez, M Manana, JI Rodríguez… - IET Renewable …, 2019 - Wiley Online Library
Power quality events associated with the occurrence of ferroresonances in medium voltage
(MV) isolated‐neutral distribution power systems are well known but they still happen in …