Performance analysis of a passive magnetic fault current limiter under the influence of shorting ring

S Das, AB Choudhury, T Santra… - … conference on control …, 2021 - ieeexplore.ieee.org
The magnetic state in the Permanent Magnet Fault Current Limiter (PMFCL) changes from
saturation to unsaturation when fault occurs in the system. Due to this nonlinear …

Analysis of Magnetic fault current limiter for faults initiating at different positions of a current waveform

S Das, AB Choudhury, T Santra - 2022 international conference …, 2022 - ieeexplore.ieee.org
Power System Faults may occur at any instance of the voltage waveform like the mean
position or the peak position or at any moment in between. To protect all the connected load …

Analysis of permanent magnet fault current limiter considering faults occurring at various position of a rectifier circuit load

S Das, AB Choudhury, T Santra, CK Chanda - Microsystem Technologies, 2023 - Springer
The fault level is increasing day-by-day due to huge expansion of electrical network. To
cope with the increasing fault level, Fault Current Limiter (FCL) is a good solution. Presently …

Finite element analysis of a passive magnetic fault current limiter using adaptive meshing

S Das, AB Choudhury, T Santra, TS Daphadar - 2021 - IET
In today's world, one of the strongest techniques of analyzing any complicated structures on
the platform of computer software is finite-element method (FEM). ANSYS is one of such …

Estimating and minimizing the eddy current loss in a permanent magnetic fault current limiter

S Das, T Santra, AB Choudhury, D Roy… - International Journal of …, 2024 - degruyter.com
This research paper represents the estimation and reduction of eddy current loss in a
Magnetic Fault Current Limiter (MFCL). The nonlinear model of the device is established …

A dual purpose passive magnetic fault current limiter for obtaining variable impedance and current suppression at fault

AK Mondal, T Santra, S Pramanik… - Michael Faraday IET …, 2020 - ieeexplore.ieee.org
A permanent magnet-biased fault current limiter (PMFCL) is a device which is designed to
limit the fault currents in electrical power system effectively and protect existing power …

Performance Evaluation of a Permanent Magnetic Fault Current Limiter at Various Supply Voltages

S Das, AB Choudhury, T Santra - 2023 5th International …, 2023 - ieeexplore.ieee.org
In this era, with the development of technology and with the increase of population the
demand for power and energy is increasing day by day. This results in the increase of fault …