Oxygen saturation and heart rate in healthy term and late preterm infants with delayed cord clamping
I Lara-Cantón, S Badurdeen, J Dekker, P Davis… - Pediatric …, 2024 - nature.com
Blood oxygen in the fetus is substantially lower than in the newborn infant. In the minutes
after birth, arterial oxygen saturation rises from around 50–60% to 90–95%. Initial respiratory …
after birth, arterial oxygen saturation rises from around 50–60% to 90–95%. Initial respiratory …
Significance of Neonatal Heart Rate in the Delivery Room—A Review
E Nerdrum Aagaard, AL Solevåg, OD Saugstad - Children, 2023 - mdpi.com
Background: Heart rate (HR) is considered the main vital sign in newborns during perinatal
transition, with a threshold of 100 beats per minute (bpm), below which, intervention is …
transition, with a threshold of 100 beats per minute (bpm), below which, intervention is …
Physiologically based cord clamping for infants ≥32+0 weeks gestation: A randomised clinical trial and reference percentiles for heart rate and oxygen saturation for infants ≥ …
S Badurdeen, PG Davis, SB Hooper, S Donath… - PLoS …, 2022 - journals.plos.org
Background Globally, the majority of newborns requiring resuscitation at birth are full term or
late-preterm infants. These infants typically have their umbilical cord clamped early (ECC) …
late-preterm infants. These infants typically have their umbilical cord clamped early (ECC) …
Comparison of heart rate feedback from dry-electrode ECG, 3-lead ECG, and pulse oximetry during newborn resuscitation
S Rettedal, J Eilevstjønn, A Kibsgaard, JT Kvaløy… - Children, 2021 - mdpi.com
Background: Assessment of heart rate (HR) is essential during newborn resuscitation, and
comparison of dry-electrode ECG technology to standard monitoring by 3-lead ECG and …
comparison of dry-electrode ECG technology to standard monitoring by 3-lead ECG and …
Heart rate detection properties of dry-electrode ECG compared to conventional 3-lead gel-electrode ECG in newborns
H Pike, J Eilevstjønn, P Bjorland, J Linde, H Ersdal… - BMC Research …, 2021 - Springer
Objective To compare the accuracy of heart rate detection properties of a novel, wireless, dry-
electrode electrocardiogram (ECG) device, NeoBeat®, to that of a conventional 3-lead gel …
electrode electrocardiogram (ECG) device, NeoBeat®, to that of a conventional 3-lead gel …
Newborns requiring resuscitation: Two thirds have heart rate≥ 100 beats/minute in the first minute after birth
A Kibsgaard, H Ersdal, JT Kvaløy, J Eilevstjønn… - Acta …, 2023 - Wiley Online Library
Aim The aim was to study the prevalence of bradycardia at birth in newborns requiring
positive pressure ventilation (PPV), distribution of first measured heart rate (HR), changes in …
positive pressure ventilation (PPV), distribution of first measured heart rate (HR), changes in …
Electrocardiogram for heart rate evaluation during preterm resuscitation at birth: a randomized trial
NV Abbey, V Mashruwala, HM Weydig… - Pediatric …, 2022 - nature.com
Background Although electrocardiogram (ECG) can detect heart rate (HR) faster compared
to pulse oximetry, it remains unknown if routine use of ECG for delivery room (DR) …
to pulse oximetry, it remains unknown if routine use of ECG for delivery room (DR) …
[HTML][HTML] Automatic prediction of therapeutic activities during newborn resuscitation combining video and signal data
Newborn mortality is a global challenge with around 2.4 million neonatal deaths in 2019.
One third of these occur within the first-and-only day of life with labour complications and …
One third of these occur within the first-and-only day of life with labour complications and …
Novel neonatal simulator provides high-fidelity ventilation training comparable to real-life newborn ventilation
J Haynes, P Bjorland, Ø Gomo, A Ushakova, S Rettedal… - Children, 2021 - mdpi.com
Face mask ventilation of apnoeic neonates is an essential skill. However, many non-
paediatric healthcare personnel (HCP) in high-resource childbirth facilities receive little …
paediatric healthcare personnel (HCP) in high-resource childbirth facilities receive little …
A randomised controlled study of low-dose high-frequency in-situ simulation training to improve newborn resuscitation
J Haynes, S Rettedal, J Perlman, H Ersdal - Children, 2021 - mdpi.com
Positive pressure ventilation of the non-breathing newborn is a critical and time-sensitive
intervention, considered to be the cornerstone of resuscitation. Many healthcare providers …
intervention, considered to be the cornerstone of resuscitation. Many healthcare providers …