What global diastolic function is, what it is not, and how to measure it

CS Chung, L Shmuylovich… - American Journal of …, 2015 - journals.physiology.org
Despite Leonardo da Vinci's observation (circa 1511) that “the atria or filling chambers
contract together while the pumping chambers or ventricles are relaxing and vice versa,” the …

Diastolic function in heart failure

SJ Kovács - Clinical Medicine Insights: Cardiology, 2015 - journals.sagepub.com
Heart failure has reached epidemic proportions, and diastolic heart failure or heart failure
with preserved ejection fraction (HFpEF) constitutes about 50% of all heart failure …

Fractionating E-wave deceleration time into its stiffness and relaxation components distinguishes pseudonormal from normal filling

S Mossahebi, S Zhu, SJ Kovács - Circulation: Cardiovascular …, 2015 - Am Heart Assoc
Background—Pseudonormal Doppler E-wave filling patterns indicate diastolic dysfunction
but are indistinguishable from the normal filling pattern. For accurate classification …

Kinematic analysis of diastolic function using the freely available software Echo E-waves–feasibility and reproducibility

MG Sundqvist, K Salman, P Tornvall, M Ugander - BMC Medical Imaging, 2016 - Springer
Background Early diastolic left ventricular (LV) filling can be accurately described using the
same methods used in classical mechanics to describe the motion of a loaded spring as it …

Quantifying Diastolic Function: From E-Waves as Triangles to Physiologic Contours via the 'Geometric Method'

M Golman, W Padovano, L Shmuylovich… - Cardiovascular …, 2018 - Springer
Conventional echocardiographic diastolic function (DF) assessment approximates
transmitral flow velocity contours (Doppler E-waves) as triangles, with peak (E peak) …

Mechanistic validation of the 2016 American Society of Echocardiography/European Association of Cardiovascular Imaging Guidelines for the assessment of diastolic …

YH Goldberg, D Megyessi, M Flam, DM Spevack… - Cardiovascular …, 2020 - Springer
Abstract Background The American Society for Echocardiography/European Association of
Cardiovascular Imaging (ASE/EACVI) 2016 guidelines for assessment of diastolic …

[PDF][PDF] Ythan H. Goldberg1, David Megyessi2, Mischa Flam2, Daniel M. Spevack3, Martin G. Sundqvist4 and

M Ugander - 2020 - cardiovascularultrasound …
Abstract Background: The American Society for Echocardiography/European Association of
Cardiovascular Imaging (ASE/EACVI) 2016 guidelines for assessment of diastolic …

[PDF][PDF] Ventricular Structure and Function

E Fractionating, RCD Pseudonormal, FN Filling - 2015 - academia.edu
Background—Pseudonormal Doppler E-wave filling patterns indicate diastolic dysfunction
but are indistinguishable from the normal filling pattern. For accurate classification …

[图书][B] Echocardiography in Myocardial Infarction: Aspects on Diastolic Function and Evaluation by Cardiovascular Magnetic Resonance Imaging

MG Sundqvist - 2023 - search.proquest.com
Background Echocardiography is routinely used to evaluate patients with known or
suspected myocardial infarction (MI). Cardiovascular magnetic resonance imaging (CMR) …

[图书][B] Kinematic Characterization of Left Ventricular Chamber Stiffness and Relaxation

S Mossahebi - 2014 - search.proquest.com
Heart failure is the most common cause of hospitalization today, and diastolic heart failure
accounts for 40-50% of cases. Therefore, it is critical to identify diastolic dysfunction at a …