Under voltage load shedding and penetration of renewable energy sources in distribution systems: a review

S Sundarajoo, DM Soomro - International Journal of Modelling and …, 2023 - Taylor & Francis
The growing energy demand and the emerging environmental concerns across the globe
caused increasing penetration of renewable energy sources (RESs) in distribution systems …

A new restoration strategy in microgrids after a blackout with priority in critical loads

V Vita, G Fotis, C Pavlatos, V Mladenov - Sustainability, 2023 - mdpi.com
The danger of a total blackout in a wide area or, even worse, in a country is always present.
The restoration methods after a blackout mainly focus on the strategy that the dispatchers in …

UFLS and smart load for frequency regulation in electrical power system—A Review

S Bustamante, JW González, GJ López… - IEEE …, 2023 - ieeexplore.ieee.org
The frequency of an electrical power system can be interpreted as an indicator of the
equilibrium between generation and demand. Under fault conditions where this balance is …

A new optimal under-voltage load shedding scheme for voltage collapse prevention in a multi-microgrid system

P Pourghasem, H Seyedi, K Zare - Electric Power Systems Research, 2022 - Elsevier
In this paper, a new optimal under-voltage load shedding (UVLS) method is presented to
maintain voltage stability of a multi-microgrid (MMG) system. Great benefits are gained by …

Power hardware in-the-loop testing to analyze fault behavior of smart inverters in distribution networks

TS Ustun, S Sugahara, M Suzuki, J Hashimoto, K Otani - Sustainability, 2020 - mdpi.com
Deep penetration of distributed generators have created several stability and operation
issues for power systems. In order to address these, inverters with advanced capabilities …

Optimal load shedding for voltage collapse prevention following overloads in distribution system

S Sundarajoo, DM Soomro - International Journal of Engineering, 2023 - ije.ir
Load shedding is generally regarded as the final option to evade voltage collapse and
blackout following major overloads. The traditional method of load shedding curtails random …

Non-iterative, unique, and logical formula-based technique to determine maximum load multiplier and practical load multiplier for both transmission and distribution …

S Nandi, SR Ghatak, P Acharjee, F Lopes - Energies, 2023 - mdpi.com
In recent days, due to the increasing number of electric vehicle charging stations (EVCSs)
and additional power consumption by domestic, commercial, and industrial consumers, the …

Distributed Synchronous generation ride-through enhancement by anti-islanding protection blocking

G Marchesan, K Maresch, G Cardoso Jr… - Electric Power Systems …, 2021 - Elsevier
Fault and other perturbations in the distribution or subtransmission system can change the
system voltage and frequency, leading to improper operation of anti-islanding protections …

Under frequency protection enhancement of an islanded active distribution network using a virtual inertia-controlled-battery energy storage system

K Hongesombut, S Punyakunlaset, S Romphochai - Sustainability, 2021 - mdpi.com
When an islanding condition caused by an unintentional single-line to ground fault occurs in
an active distribution network with distributed generation, the frequency stability and …

An adaptive under-frequency optimal control strategy for power system combined pumped storage and under-frequency load shedding

W Huang, J Yu, Z Yuan, Z He, J He, M Deng - Plos one, 2021 - journals.plos.org
With the construction and development of ultra-high voltage (UHV) power grids, large-scale,
long-distance power transmission has become common. A failure of the connecting line …