Evaluation of a new VMAT QA device, or the “X” and “O” array geometries

V Feygelman, G Zhang, C Stevens… - Journal of applied …, 2011 - Wiley Online Library
We introduce a logical process of three distinct phases to begin the evaluation of a new 3D
dosimetry array. The array under investigation is a hollow cylinder phantom with diode …

Verification of dosimetric accuracy on the TrueBeam STx: rounded leaf effect of the high definition MLC

KN Kielar, E Mok, A Hsu, L Wang, G Luxton - Medical physics, 2012 - Wiley Online Library
Purpose: The dosimetric leaf gap (DLG) in the Varian Eclipse treatment planning system is
determined during commissioning and is used to model the effect of the rounded leaf‐end of …

Challenges in modeling the Agility multileaf collimator in treatment planning systems and current needs for improvement

V Hernandez, A Angerud, E Bogaert… - Medical …, 2022 - Wiley Online Library
Abstract Background The Agility multileaf collimator (MLC) mounted in Elekta linear
accelerators features some unique design characteristics, such as large leaf thickness …

EPID‐based verification of the MLC performance for dynamic IMRT and VMAT

P Rowshanfarzad, M Sabet, MP Barnes… - Medical …, 2012 - Wiley Online Library
Purpose: In advanced radiotherapy treatments such as intensity modulated radiation therapy
(IMRT) and volumetric modulated arc therapy (VMAT), verification of the performance of the …

Determining the optimal dosimetric leaf gap setting for rounded leaf‐end multileaf collimator systems by simple test fields

W Yao, JB Farr - Journal of Applied Clinical Medical Physics, 2015 - Wiley Online Library
Individual QA for IMRT/VMAT plans is required by protocols. Sometimes plans cannot pass
the institute's QA criteria. For the Eclipse treatment planning system (TPS) with rounded leaf …

Experimental investigation of the response of an amorphous silicon EPID to intensity modulated radiotherapy beams

PB Greer, P Vial, L Oliver, C Baldock - Medical physics, 2007 - Wiley Online Library
The aim of this work was to experimentally determine the difference in response of an
amorphous silicon electronic portal imaging device (EPID) to the open and multileaf …

Commissioning of and preliminary experience with a new fully integrated computed tomography linac

L Yu, J Zhao, Z Zhang, J Wang… - Journal of Applied Clinical …, 2021 - Wiley Online Library
Purpose A new medical linear accelerator (linac) platform integrated with helical computed
tomography (CT), the uRT‐linac 506c, was introduced into clinical application in 2019 by …

On using the dosimetric leaf gap to model the rounded leaf ends in VMAT/RapidArc plans

S Szpala, F Cao, K Kohli - Journal of applied clinical medical …, 2014 - Wiley Online Library
Partial transmission through rounded leaf ends of Varian multileaf collimators (MLC) is
accounted for with a parameter called the dosimetric leaf gap (DLG). Verification of the value …

A novel procedure for determining the optimal MLC configuration parameters in treatment planning systems based on measurements with a Farmer chamber

J Saez, V Hernandez, J Goossens… - Physics in Medicine …, 2020 - iopscience.iop.org
Modelling of the multi-leaf collimator (MLC) in treatment planning systems (TPS) is crucial for
the dose calculation accuracy of intensity-modulated radiation therapy plans. However, no …

Dosimetric characterization of the dual layer MLC system for an O-ring linear accelerator

MM Kim, D Bollinger, C Kennedy… - … in cancer research …, 2019 - journals.sagepub.com
The Halcyon is Varian's latest linear accelerator that offers a single 6X flattening-filter-free
beam with a jawless design that features a new dual layer multileaf collimator system with …