High surge impedance loading (HSIL) lines: A review identifying opportunities, challenges, and future research needs

M Ghassemi - IEEE Transactions on Power Delivery, 2019 - ieeexplore.ieee.org
Making old new again: next generation of self-reactive power compensation high surge
impedance loading (HSIL) lines engaging transmission expansion planning (TEP) can be a …

[HTML][HTML] A comprehensive review on magnetically controllable reactor: Modelling, applications and future prospects

K Mehmood, KM Cheema, MF Tahir, A Saleem… - Energy Reports, 2021 - Elsevier
Renewable energy sources are commonly available on earth; thus, both research and
practical applications have drawn significant interest. In the large-scale renewable energy …

Protection scheme for turn-to-turn faults of magnetically controlled shunt reactor based on waveform similarity comparison

T Zheng, X Liu, J Wei, MA Khan, X Wang - Electric Power Systems …, 2019 - Elsevier
Magnetically controlled shunt reactor (MCSR) is one of the key elements applied in
EHV/UHV transmission systems for reactive power compensation and overvoltage …

[HTML][HTML] Minimizing the harmonics generated in magnetically controllable reactors by shaping the iron core using the variational method and Gauss–Legendre integral

M Yang, B Chen, C Tian, F Wu, Z Guo - Energy Reports, 2023 - Elsevier
Magnetically controllable reactors (MCRs) are widely used to flexibly control reactive power
flow in power systems. However, owing to the nonlinear characteristics of saturation of the …

Analysis of electrical length compensation types for tuned half-wavelength transmission lines

P Cao, H Shu, B Yang, S Li, T He, L Yang… - International Journal of …, 2020 - Elsevier
The compensation circuits are the core to improve the flexibility of practical application of
half-wavelength transmission lines (HWTL), which are restricted to the fixed transmission …

Novel protection scheme against turn-to-turn fault of magnetically controlled shunt reactor based on equivalent leakage inductance

T Zheng, X Liu, T Huang - International Journal of Electrical Power & …, 2019 - Elsevier
Magnetically controlled shunt reactors (MCSRs) are key elements of extra-high voltage/ultra-
high voltage (EHV/UHV) transmission systems for reactive power compensation and …

[HTML][HTML] Calculation of core hysteresis loss resistance for Buntenbach's analogy hysteresis model

H Zhang, Y Shen, M Tian, T Wang, W Tian - AIP Advances, 2024 - pubs.aip.org
The value for core hysteresis loss (CHL) resistance in Buntenbach's analogy hysteresis
model does not consider the impact of frequency variations. In order to address this issue …

Mechanical fault diagnosis of reactor core winding looseness based on multi-feature fusion and improved KELM

P Hou, H Ma, B Liu, X Chen, C Zhu… - 2021 IEEE Sustainable …, 2021 - ieeexplore.ieee.org
To solve the problems of frequent occurrence of loose cores of high-voltage shunt reactor
(HVSR) windings and low operating efficiency, this paper proposes a fault diagnosis method …

Effect of magnetization curve model and winding connection mode on magnetically saturated controllable reactor based on ANSYS

H Zhang, M Tian, P Jing - 2019 22nd International Conference …, 2019 - ieeexplore.ieee.org
In order to guide the selection of magnetization curve model in modeling and provide useful
information for the application of winding connection mode in structure design, it is …

Design and Modelling of LLCL Filter for Real-time Harmonic Mitigation with Actual Prototype Implementation for Monitoring of Signal Variation using Fast Fourier …

JR Balbin, JRO Aguilar, IR Guieb… - 2020 IEEE 12th …, 2020 - ieeexplore.ieee.org
The sudden progression of power electronics-based devices and appliances in the recent
years has led to a problem quality in electrical energy to the users due to the harmonics …