Fault current limiters in power systems: A comprehensive review

MS Alam, MAY Abido, I El-Amin - Energies, 2018 - mdpi.com
Power systems are becoming more and more complex in nature due to the integration of
several power electronic devices. Protection of such systems and augmentation of reliability …

AC microgrid protection schemes: A comprehensive review

WM Hamanah, MI Hossain, M Shafiullah… - IEEE Access, 2023 - ieeexplore.ieee.org
The power grid infrastructure has evolved from a centralized to a distributed model utilizing
renewable energy sources in the last few years. This trend is likely to continue, given the …

Superconducting fault current limiter (SFCL): Experiment and the simulation from finite-element method (FEM) to power/energy system software

B Shen, Y Chen, C Li, S Wang, X Chen - Energy, 2021 - Elsevier
The superconducting fault current limiter (SFCL) has been regarded as one of most popular
superconducting applications. This article reviews the modern energy system with two major …

Analyzing integrated renewable energy and smart-grid systems to improve voltage quality and harmonic distortion losses at electric-vehicle charging stations

A Khan, S Memon, TP Sattar - IEEE Access, 2018 - ieeexplore.ieee.org
Increasing the use of electric vehicles (EVs) is regarded as a step in the right direction to
reduce air pollution and carbon emissions. However, a dramatic increase of EV and …

Optimized series dynamic braking resistor for LVRT of doubly-fed induction generator with uncertain fault scenarios

J Huang, L Zhang, S Sang, X Xue, X Zhang… - IEEE …, 2022 - ieeexplore.ieee.org
The terminal-connected series dynamic braking resistor (SDBR) is applied to assist the low-
voltage ride-through (LVRT) of the doubly-fed induction generator (DFIG). With the fault …

A cooperative approach of frequency regulation through virtual inertia control and enhancement of low voltage ride-through in DFIG-based wind farm

P Verma, K Seethalekshmi… - Journal of Modern Power …, 2021 - ieeexplore.ieee.org
Doubly-fed induction generator (DFIG)-based wind farms (WFs) are interfaced with power
electronic converters. Such interfaces are attributed to the low inertia generated in the WFs …

Discontinuous-modulation-based active thermal control of power electronic modules in wind farms

Y Ko, M Andresen, G Buticchi… - IEEE Transactions on …, 2018 - ieeexplore.ieee.org
With the increasing renewable energy injected into the electrical distribution grid, the
reliability of the power converter is gaining importance for the power system. In order to …

Fault detection and classification in transmission lines connected to inverter-based generators using machine learning

K Al Kharusi, A El Haffar, M Mesbah - Energies, 2022 - mdpi.com
Integrating inverter-based generators in power systems introduces several challenges to
conventional protection relays. The fault characteristics of these generators depend on the …

Comparative study of the effects of machine parameters on DFIG and PMSG variable speed wind turbines during grid fault

KE Okedu, M Al Tobi, S Al Araimi - Frontiers in Energy Research, 2021 - frontiersin.org
This study investigates the transient performance of two variable speed wind turbines
(VSWTs), namely doubly fed induction generator (DFIG) and the permanent magnet …

Enhancing fault ride‐through capability of DFIG with modified SMES‐FCL and RSC control

XY Xiao, RH Yang, XY Chen… - IET Generation …, 2018 - Wiley Online Library
For grid‐connected doubly fed induction generators (DFIGs), fault ride‐through (FRT)
capability and transient stability are vital problems that urgently need to be addressed. To …