Short-circuit fault diagnosis based on RS-GA-BN for single-phase H-bridge inverters
H Sumin, S Zhihao, Z Meng, H Pinghua - Electrical Engineering, 2023 - Springer
Short-circuit (SC) of power components in inverters is one of the most serious faults that are
vulnerable to occur. It is critical to quickly and accurately detect and locate SC faults in …
vulnerable to occur. It is critical to quickly and accurately detect and locate SC faults in …
Double Normalization Fault Diagnosis Method for Open-Circuit Faults of PMSM Drives
In this article, a double normalization fault diagnosis (DNFD) method is proposed to cope
with open-circuit faults of PMSM drives. The proposed DNFD method consists of the current …
with open-circuit faults of PMSM drives. The proposed DNFD method consists of the current …
Open-Circuit Fault-Tolerant Method for Half-Bridge Switches of Three-Level Quasi-Switched Boost T-Type Inverter to Improve Voltage Gain
The three-level quasi-switched boost T-type inverter (3L-qSBT2I) can feature buck-boost
operating and shoot-through (ST) immunity with high voltage gain and low component …
operating and shoot-through (ST) immunity with high voltage gain and low component …
[PDF][PDF] 一种抑制三相准开关升压逆变器电感电流纹波的空间矢量调制方法
董帅, 林晨, 张千帆, 张潍攀, 朱春波 - 电工技术学报, 2022 - dgjsxb.ces-transaction.com
摘要高频电流纹波影响了变换器电感体积和质量, 针对准开关升压逆变器,
传统的直通调制算法并不能做到电感电流纹波最小. 该文提出一种最小电感电流纹波的空间矢量 …
传统的直通调制算法并不能做到电感电流纹波最小. 该文提出一种最小电感电流纹波的空间矢量 …
A Fault Diagnosis Method in Three-Phase Voltage Inverters Based on the Normalized Current Trajectory Centroid
S Han, Z Shang, Y Guo, X Jia - Journal of Electrical Engineering & …, 2024 - Springer
A fault diagnosis method based on the normalized current trajectory centroid is proposed for
open-circuit and short-circuit faults in three-phase voltage inverters. The method involves …
open-circuit and short-circuit faults in three-phase voltage inverters. The method involves …
[PDF][PDF] Distributed generation on phase-to-phase short circuit protection in distribution network
B Alexis - Distributed Processing System, 2020 - scholar-press.com
As the distributed generation (DG) is connected to the distribution network, the network
structure of the original distribution network will change, and the original phase-to-phase …
structure of the original distribution network will change, and the original phase-to-phase …
Suppression of Neutral Point Potential Drift on DC Bus for Fault-Tolerant APF
W Li, C Yue, Y Zhang - Journal of Electrical Engineering & Technology, 2021 - Springer
The control performance of the APF is affected by neutral point potential drift of the DC bus
when the APF runs in the fault-tolerant mode; thus, in this paper, a compensation method of …
when the APF runs in the fault-tolerant mode; thus, in this paper, a compensation method of …
[PDF][PDF] Review of impedance source power converter for electrical applications
V Saravanan, KM Venkatachalam, M Arumugam… - Int J Adv Appl Sci … - academia.edu
Power electronic converters have been actively researched and developed over the past
decades. There is a growing need for new solutions and topography to increase the …
decades. There is a growing need for new solutions and topography to increase the …
Analysis of Short Circuit Fault Detection of Power Switch of Impedance-source Inverter Based on Shoot-through Characteristic
F Xupeng, Z Shicheng, L Chenna… - 2020 Chinese …, 2020 - ieeexplore.ieee.org
This paper carried out the detection research on the power switch short circuit fault of the
three-phase Impedance-source inverter. Based on the shoot-through characteristics of the …
three-phase Impedance-source inverter. Based on the shoot-through characteristics of the …