Genetic algorithm optimization of tin–copper graded shielding for improved plutonium safeguards measurements

N Kleedtke, M Hua, S Pozzi - Nuclear Instruments and Methods in Physics …, 2021 - Elsevier
Plutonium nuclear material safeguards is essential to ensure that states do not divert
plutonium to clandestine nuclear weapons programs. Traditional safeguards methods rely …

Characterizing scintillator detector response for correlated fission experiments with MCNP and associated packages

MT Andrews, ME Rising, K Meierbachtol… - Radiation Physics and …, 2019 - Elsevier
When multiple neutrons are emitted in a fission event they are correlated in both energy and
their relative angle, which may impact the design of safeguards equipment and other …

Gamma/neutron time-correlation for special nuclear material detection–Active stimulation of highly enriched uranium

MG Paff, M Monterial, P Marleau, S Kiff, A Nowack… - Annals of Nuclear …, 2014 - Elsevier
The time-correlated pulse-height technique can distinguish multiplying (special nuclear
material) from non-multiplying sources. The technique relies upon the measurement of …

MPACT fast neutron multiplicity system design concepts

DL Chichester, SA Pozzi, JL Dolan, MT Kinlaw… - 2012 - osti.gov
This report documents work performed by Idaho National Laboratory and the University of
Michigan in fiscal year (FY) 2012 to examine design parameters related to the use of fast …

Characterization of Fissionable Material using a Time-Correlated Pulse-Height Technique for Liquid Scintillators.

EC Miller - 2012 - deepblue.lib.umich.edu
In recent years, the threat of an extremist group obtaining and using a nuclear weapon has
moved to the forefront of nuclear security concerns. Fortunately, the production of special …

Organic Scintillators in Nonproliferation Applications With a Hybridized Double-Pulse Rejection Technique.

MM Bourne - 2016 - deepblue.lib.umich.edu
Alternative detection technologies are crucial to meeting demand for neutron detectors, for
the current production of He-3, which has been the classical neutron choice, is insufficient …

MPACT fast neutron multiplicity system prototype development

DL Chichester, SA Pozzi, JL Dolan, MT Kinlaw… - 2013 - osti.gov
This document serves as both an FY2103 End-of-Year and End-of-Project report on efforts
that resulted in the design of a prototype fast neutron multiplicity counter leveraged upon the …

Safeguarding Special Nuclear Material by Detecting Fast Neutrons in Liquid Scintillators.

JL Dolan - 2013 - deepblue.lib.umich.edu
The number and complexity of nuclear facilities are increasing and new technologies are
needed to maintain successful domestic and international safeguards efforts. Specifically …

Passive measurement of organic-scintillator neutron signatures for nuclear safeguards applications

JL Dolan, EC Miller, AC Kaplan… - 2012 IEEE Nuclear …, 2012 - ieeexplore.ieee.org
At nuclear facilities, domestically and internationally, most measurement systems used for
nuclear materials' control and accountability rely on He-3 detectors. Due to resource …

Estimation of fissile material content in irradiated In-Pile Sections using neutron coincidence counters

R Rossa, A Borella, S Boden… - EPJ Web of …, 2020 - epj-conferences.org
A set of In-Pile Sections (IPS) has been irradiated in the BR2 reactor at SCK• CEN in
Belgium during the 1970's and 1980's. The primary goal of the IPS was to replicate the …