The physics of solid-state neutron detector materials and geometries
AN Caruso - Journal of Physics: Condensed Matter, 2010 - iopscience.iop.org
Detection of neutrons, at high total efficiency, with greater resolution in kinetic energy, time
and/or real-space position, is fundamental to the advance of subfields within nuclear …
and/or real-space position, is fundamental to the advance of subfields within nuclear …
Gadolinium for neutron detection in current nuclear instrumentation research: A review
J Dumazert, R Coulon, Q Lecomte… - Nuclear Instruments and …, 2018 - Elsevier
Natural gadolinium displays a number of remarkable physical properties: it is a rare earth
element, composed of seven stable or quasi-stable isotopes, with an exceptionally high …
element, composed of seven stable or quasi-stable isotopes, with an exceptionally high …
[HTML][HTML] Use of GEANT4 vs. MCNPX for the characterization of a boron-lined neutron detector
BM Van Der Ende, J Atanackovic, A Erlandson… - Nuclear Instruments and …, 2016 - Elsevier
This work compares GEANT4 with MCNPX in the characterization of a boron-lined neutron
detector. The neutron energy ranges simulated in this work (0.025 eV to 20 MeV) are the …
detector. The neutron energy ranges simulated in this work (0.025 eV to 20 MeV) are the …
Effect of wedge filter and field size on photoneutron dose equivalent for an 18 MV photon beam of a medical linear accelerator
Photoneutrons produced during radiation therapy with high energy photons is the main
source of unwanted out-of-field received doses of patients. To analyze the neutron dose …
source of unwanted out-of-field received doses of patients. To analyze the neutron dose …
[HTML][HTML] Enhancement of radiation effectiveness in proton therapy: comparison between fusion and fission methods and further approaches
F Tabbakh, NS Hosmane - Scientific Reports, 2020 - nature.com
Proton therapy as a promising candidate in cancer treatment has attracted much attentions
and many studies have been performed to investigate the new methods to enhance its …
and many studies have been performed to investigate the new methods to enhance its …
Dosimetry for gadolinium neutron capture therapy (GdNCT)
Abstract Background Gadolinium (Gd) neutron capture therapy (GdNCT) is based on a
neutron capture reaction (NCR) that involves emission of both short and long range …
neutron capture reaction (NCR) that involves emission of both short and long range …
Effect of each component of a LINAC therapy head on neutron and photon spectra
R Khabaz - Applied Radiation and Isotopes, 2018 - Elsevier
Linear accelerators (LINACs) are widely applied in radiotherapy for their versatility and
flexibility. Monte Carlo simulations were made to find the neutron and photon spectra at the …
flexibility. Monte Carlo simulations were made to find the neutron and photon spectra at the …
Octree indexing of DICOM images for voxel number reduction and improvement of Monte Carlo simulation computing efficiency
V Hubert‐Tremblay, L Archambault, D Tubic… - Medical …, 2006 - Wiley Online Library
The purpose of the present study is to introduce a compression algorithm for the CT
(computed tomography) data used in Monte Carlo simulations. Performing simulations on …
(computed tomography) data used in Monte Carlo simulations. Performing simulations on …
Comparison of the neutron ambient dose equivalent and ambient absorbed dose calculations with different GEANT4 physics lists
RM Ribeiro, D Souza-Santos - Radiation Physics and Chemistry, 2017 - Elsevier
A comparison between neutron physics lists given by GEANT4, is made in the calculation of
the ambient dose equivalent, and ambient absorbed dose, per fluence conversion …
the ambient dose equivalent, and ambient absorbed dose, per fluence conversion …
GEANT4 calculations of neutron dose in radiation protection using a homogeneous phantom and a Chinese hybrid male phantom
The purpose of this study is to verify the feasibility of applying GEANT4 (version 10.01) in
neutron dose calculations in radiation protection by comparing the calculation results with …
neutron dose calculations in radiation protection by comparing the calculation results with …