Intraocular lens optic edge design for the prevention of posterior capsule opacification after cataract surgery

S Maedel, JR Evans, A Harrer-Seely… - Cochrane Database of …, 2021 - cochranelibrary.com
Background Posterior capsule opacification (PCO) is a clouding of the posterior part of the
lens capsule, a skin‐like transparent structure, which surrounds the crystalline lens in the …

Extended depth of focus intraocular lens. Chromatic performance

MS Millán, F Vega - Biomedical optics express, 2017 - opg.optica.org
We describe a first-and-second-diffractive-order intraocular lens ((1^ st, 2^ nd) DIOL) within
the class of hybrid refractive-diffractive designs for intraocular lenses (IOLs) and analyse its …

Visual acuity, defocus curve and patient satisfaction of a new hybrid EDOF-multifocal diffractive intraocular lens

C Ozturkmen, C Kesim… - European Journal of …, 2022 - journals.sagepub.com
Purpose: To evaluate the visual acuity, defocus curve and visual quality of life following
bilateral implantation of a new hybrid extended depth of focus (EDOF)-multifocal diffractive …

Prediction of visual acuity and contrast sensitivity from optical simulations with multifocal intraocular lenses

J Fernández, M Rodríguez-Vallejo… - Journal of Refractive …, 2019 - journals.healio.com
PURPOSE: To evaluate whether the prediction of visual performance based on the
modulation transfer function area (MTFa) calculated with optical simulations is better …

Visual acuity of pseudophakic patients predicted from in-vitro measurements of intraocular lenses with different design

F Vega, MS Millán, N Garzón, I Altemir… - Biomedical optics …, 2018 - opg.optica.org
The optical quality of a set of IOLs (modeling set: one monofocal and two bifocals) was
assessed through focus by the area under the modulation transfer function (MTFa) metric …

Binocular and monocular implantation of small-aperture intraocular lenses in cataract surgery

HB Dick, M Elling, T Schultz - Journal of Refractive Surgery, 2018 - journals.healio.com
PURPOSE: To compare the clinical outcomes with the extended depth of focus small-
aperture intraocular lens (IOL)(IC-8; AcuFocus, Irvine, CA) for presbyopia compensation …

Comparison of visual and optical quality of monofocal versus multifocal intraocular lenses

I Altemir-Gomez, MS Millan, F Vega… - European journal of …, 2020 - journals.sagepub.com
Objective: To compare visual quality in patients implanted with Tecnis® monofocal (ZCB00)
and multifocal (ZMB00) intraocular lenses taking into account their optical quality measured …

A clinical assessment of visual performance of combining the TECNIS® Symfony Extended Range of Vision IOL (ZXR00) with the +3.25 D TECNIS Multifocal 1-piece …

S Black - Clinical Ophthalmology, 2018 - Taylor & Francis
Purpose To combine the increased depth of focus of the TECNIS® Symfony intraocular lens
(IOL) with a TECNIS Multifocal (MF) low-add IOL (+ 3.25) to enable a patient to be less …

Impact of pupil size and corneal spherical aberrations on the performance of monofocal intraocular lenses: an experimental model

B Stern, D Gatinel - Biomedical Optics Express, 2024 - opg.optica.org
In this study, an in vitro comparison of the optical performances of three models (spherical,
aberration-neutral, and aberration-correcting) of monofocal intraocular lenses (IOLs) is …

Comparative efficacy and safety of all kinds of intraocular lenses in presbyopia-correcting cataract surgery: a systematic review and meta-analysis

J Li, B Sun, Y Zhang, Y Hao, Z Wang, C Liu, S Jiang - BMC ophthalmology, 2024 - Springer
Purpose To assess the efficacy and safety of various intraocular lenses (IOLs), including
standard monofocal, bifocal, trifocal, extended depth of focus (EDOF), and enhanced …