State-of-the-art review on the transient flow modeling and utilization for urban water supply system (UWSS) management

HF Duan, B Pan, M Wang, L Chen… - Journal of Water …, 2020 - iwaponline.com
In the context of smart city development and rapid urbanization worldwide, urban water
supply system (UWSS) has been of vital importance to this process. This paper presents a …

Transient wave-based methods for anomaly detection in fluid pipes: A review

TC Che, HF Duan, PJ Lee - Mechanical Systems and Signal Processing, 2021 - Elsevier
Over the years, anomaly detection of fluid pipes has been a focus of water authorities as well
as oil and gas operators to advance the operation and management of these mechanical …

Pipeneta wireless sensor network for pipeline monitoring

I Stoianov, L Nachman, S Madden… - Proceedings of the 6th …, 2007 - dl.acm.org
US water utilities are faced with mounting operational and maintenance costs as a result of
aging pipeline infrastructures. Leaks and ruptures in water supply pipelines and blockages …

Computational methods for pipeline leakage detection and localization: A review and comparative study

J Sekhavati, SH Hashemabadi, M Soroush - Journal of Loss Prevention in …, 2022 - Elsevier
Pipelines are one of the least expensive means of transporting fluids in long distances and
distributing fluids in large areas and cities. Fluids transported and distributed by pipelines …

The dynamic effect of pipe-wall viscoelasticity in hydraulic transients. Part II—Model development, calibration and verification

D Covas, IN Stoianov, JF Mano, H Ramos… - Journal of Hydraulic …, 2005 - Taylor & Francis
Un nouveau modèle mathématique a été développé pour calculer les régimes transitoires
hydrauliques des systèmes de conduites pressurisées en polyethylene (PE). Ce modèle …

Case studies of leak detection and location in water pipe systems by inverse transient analysis

D Covas, H Ramos - Journal of Water Resources Planning and …, 2010 - ascelibrary.org
The current paper aims at the assessment of the effectiveness of a popular transient-based
technique—inverse transient analysis (ITA)—for leak detection in water pipe systems using …

Fluid–structure interaction with pipe-wall viscoelasticity during water hammer

A Keramat, AS Tijsseling, Q Hou, A Ahmadi - Journal of Fluids and …, 2012 - Elsevier
Fluid–structure interaction (FSI) due to water hammer in a pipeline which has viscoelastic
wall behaviour is studied. Appropriate governing equations are derived and numerically …

Design criteria and performance analysis of a smart portable device for leak detection in water transmission mains

B Brunone, C Capponi, S Meniconi - Measurement, 2021 - Elsevier
In this paper, criteria for the optimal and market-oriented design of the Smart-Portable
Pressure Wave Maker (S-PPWM) device are presented. The outlined criteria are based on …

Standing wave difference method for leak detection in pipeline systems

D Covas, H Ramos, AB De Almeida - Journal of Hydraulic …, 2005 - ascelibrary.org
The current paper focuses on leakage detection in pipe systems by means of the standing
wave difference method (SWDM) used for cable fault location in electrical engineering. This …

Unsteady friction and visco-elasticity in pipe fluid transients

HF Duan, M Ghidaoui, PJ Lee… - Journal of hydraulic …, 2010 - Taylor & Francis
The current waterhammer models coupled with friction models cannot adequately represent