Quantifying glomerular filtration rates in acute kidney injury: a requirement for translational success
BA Molitoris, ES Reilly - Seminars in nephrology, 2016 - Elsevier
Acute kidney injury (AKI) remains a vexing clinical problem that results in unacceptably high
patient mortality, development of chronic kidney disease, and accelerated progression to …
patient mortality, development of chronic kidney disease, and accelerated progression to …
Hyperspectral imaging of human skin aided by artificial neural networks
We developed a compact, hand-held hyperspectral imaging system for 2D neural network-
based visualization of skin chromophores and blood oxygenation. State-of-the-art micro …
based visualization of skin chromophores and blood oxygenation. State-of-the-art micro …
Broad bandwidth frequency domain instrument for quantitative tissue optical spectroscopy
TH Pham, O Coquoz, JB Fishkin, E Anderson… - Review of scientific …, 2000 - pubs.aip.org
Near-infrared (NIR) optical properties of turbid media, eg, tissue, can be accurately
quantified noninvasively using methods based on diffuse reflectance or transmittance, such …
quantified noninvasively using methods based on diffuse reflectance or transmittance, such …
Monte Carlo study of diffuse reflectance at source–detector separations close to one transport mean free path
F Bevilacqua, C Depeursinge - JOSA A, 1999 - opg.optica.org
The spatially resolved reflectance of turbid media is studied at short source–detector
separations (approximately one transport mean free path) with Monte Carlo simulations. For …
separations (approximately one transport mean free path) with Monte Carlo simulations. For …
Perturbation Monte Carlo methods to solve inverse photon migration problems in heterogeneous tissues
We introduce a novel and efficient method to provide solutions to inverse photon migration
problems in heterogeneous turbid media. The method extracts derivative information from a …
problems in heterogeneous turbid media. The method extracts derivative information from a …
Steady-state reflectance spectroscopy in the P3 approximation
EL Hull, TH Foster - JOSA A, 2001 - opg.optica.org
The Green's function of the steady-state radiative-transport equation is derived in the P_3
approximation for isotropic sources. It is demonstrated that the P_3 approximation models …
approximation for isotropic sources. It is demonstrated that the P_3 approximation models …
Characterization of dysplastic tissue morphology and biochemistry in Barrett's esophagus using diffuse reflectance and light scattering spectroscopy
I Georgakoudi, J Van Dam - Gastrointestinal Endoscopy …, 2003 - giendo.theclinics.com
The use of color as a diagnostic or prognostic indicator has been documented since the time
of Hippocrates, when it was believed that health involved the proper balance of four humors …
of Hippocrates, when it was believed that health involved the proper balance of four humors …
Rapid multi-spectral imaging methods and apparatus and applications for cancer detection and localization
H Zeng, Y Fawzy - US Patent 9,654,745, 2017 - Google Patents
US9654745B2 - Rapid multi-spectral imaging methods and apparatus and applications for
cancer detection and localization - Google Patents US9654745B2 - Rapid multi-spectral …
cancer detection and localization - Google Patents US9654745B2 - Rapid multi-spectral …
Realtime light dosimetry software tools for interstitial photodynamic therapy of the human prostate
A Johansson, J Axelsson, S Andersson‐Engels… - Medical …, 2007 - Wiley Online Library
Photodynamic therapy (PDT) for the treatment of prostate cancer has been demonstrated to
be a safe treatment option capable of inducing tissue destruction and decreasing prostate …
be a safe treatment option capable of inducing tissue destruction and decreasing prostate …
Radiative transport in the delta-P 1 approximation: accuracy of fluence rate and optical penetration depth predictions in turbid semi-infinite media
Using the δ-P1 approximation to the Boltzmann transport equation we develop analytic
solutions for the fluence rate produced by planar (1-D) and Gaussian beam (2-D) irradiation …
solutions for the fluence rate produced by planar (1-D) and Gaussian beam (2-D) irradiation …