An iterative two-terminal fault-location method based on unsynchronized phasors

AL Dalcastagnê, S Noceti Filho… - IEEE Transactions on …, 2008 - ieeexplore.ieee.org
This paper presents a two-terminal fault-location method which works with unsynchronized
phasors. The algorithm is iterative and takes a distributed line model into account. At each …

Implementation of modal domain transmission line models in the ATP software

JSL Colqui, LCT Eraso, PT Caballero… - IEEE …, 2022 - ieeexplore.ieee.org
Electromagnetic Transients Program make extensive use of transmission line models for the
simulation of electromagnetic transients. This paper proposes a circuit representation of the …

Source Inverter Voltage and Frequency Control for AC Isolated Microgrid Applications

H Yépez, W Pavón, S Simani, E Ayala… - 2022 IEEE 7th …, 2022 - ieeexplore.ieee.org
A novel control strategy is proposed in this paper, which implements a Hierarchical Control
(HC) and Space Vector Pulse Width Modulation (SVPWM). The paper outline includes the …

Development of an experimental scaled-down frequency dependent transmission line model

KK Challa, G Gurrala - IEEE Access, 2021 - ieeexplore.ieee.org
The penetration of power electronic based equipment in the power grid has increased the co-
occurrence of electromechanical and electromagnetic transients. Significant research efforts …

New mode domain multiphase transmission line model-transformation matrix modeling

MC Tavares, J Pissolato… - POWERCON'98. 1998 …, 1998 - ieeexplore.ieee.org
This paper presents a new model to represent three-phase transmission lines in transient
studies, including the frequency dependence of longitudinal parameters. The transformation …

A two-terminal fault location approach based on unsynchronized phasors

AL Dalcastagne, S Noceti Filho… - … Conference on Power …, 2006 - ieeexplore.ieee.org
This paper presents the fundamentals of a two-terminal impedance-based fault location
algorithm for transmission lines which works with unsynchronized phasors. The proposed …

Lightning current on the frequency-dependent lumped parameter model representing short transmission lines

JSL Colqui, LC Timaná, S Kurokawa… - … (ICLP) and XVI …, 2021 - ieeexplore.ieee.org
The purpose of this paper is to investigate the performance of the Frequency-Dependent
Lumped Parameter Model (FD-LPM) to adequately represent two distinct overhead …

New multiphase transmission line model

MC Tavares, J Pissolato… - … Conference on Harmonics …, 1998 - ieeexplore.ieee.org
This paper presents a new model to represent multiphase transmission lines in transient
studies, including the frequency dependence of longitudinal parameters. The model uses …

New mode domain multiphase transmission line model applied to transient studies

MC Tavares, J Pissolato… - POWERCON'98. 1998 …, 1998 - ieeexplore.ieee.org
This article presents a new model to represent multiphase transmission lines including the
frequency dependence of longitudinal parameters. The model uses exact modes, for ideally …

A numerical study of forces for sandwiched maglev stage

N Song, S Ma, Z Zhang - International Journal of Applied …, 2017 - content.iospress.com
A novel sandwiched maglev positioning stage is proposed in this paper. Mathematical
model and finite element models are made up to analyze levitation force and driving force …