Compact CT/SPECT small-animal imaging system

GA Kastis, LR Furenlid, DW Wilson… - IEEE transactions on …, 2004 - ieeexplore.ieee.org
We have developed a dual-modality CT/SPECT imaging system for small-animal imaging
applications. The X-ray system comprises a commercially available micro-focus X-ray tube …

An intensified EMCCD camera for low energy gamma ray imaging applications

LJ Meng - IEEE transactions on nuclear science, 2006 - ieeexplore.ieee.org
This paper presents the design and feasibility study of a very-high resolution gamma camera
for detecting 27-35 keV X and gamma rays emitted by I-125 labelled radiotracers. This …

Evaluation of pinhole collimator materials for micron-resolution ex vivo SPECT

MP Nguyen, MC Goorden, C Kamphuis… - Physics in Medicine & …, 2019 - iopscience.iop.org
Pinhole collimation is widely recognized for offering superior resolution-sensitivity trade-off
in SPECT imaging of small subjects. The newly developed EXIRAD-3D autoradiography …

First results from the high-resolution mouseSPECT annular scintillation camera

AL Goertzen, DW Jones, J Seidel, K Li… - IEEE transactions on …, 2005 - ieeexplore.ieee.org
High-resolution single-photon emission computed tomography (SPECT) imaging in small
animals tends to use long imaging times and large injected doses due to the poor sensitivity …

Penetration, scatter and sensitivity in channel micro-pinholes for SPECT: a Monte Carlo investigation

F Van Der Have, FJ Beekman - IEEE transactions on nuclear …, 2006 - ieeexplore.ieee.org
Channel-edge pinhole designs have been proposed in order to reduce the penetration of
gamma rays through the edge of the pinhole aperture. A characterization of penetration and …

Dual-modality imaging: more than the sum of its components

BH Hasegawa, H Zaidi - Quantitative analysis in nuclear medicine imaging, 2006 - Springer
The field of diagnostic radiology encompasses a wealth of imaging techniques that now are
essential for evaluating and managing patients who need medical care. Traditional imaging …

Comparison of pinhole collimator materials based on sensitivity equivalence

V Bom, M Goorden, F Beekman - Physics in Medicine & Biology, 2011 - iopscience.iop.org
Pinhole SPECT often provides an excellent resolution sensitivity trade-off for radionuclide
imaging compared to SPECT with parallel holes, particularly when imaging small …

Multi-pinhole SPECT imaging with silicon strip detectors

TE Peterson, S Shokouhi, LR Furenlid… - IEEE transactions on …, 2009 - ieeexplore.ieee.org
Silicon double-sided strip detectors offer outstanding instrinsic spatial resolution with
reasonable detection efficiency for iodine-125 emissions. This spatial resolution allows for …

The performance of MLEM for dynamic imaging from simulated few-view, multi-pinhole SPECT

D Ma, P Wolf, AV Clough… - IEEE transactions on …, 2012 - ieeexplore.ieee.org
Stationary small-animal SPECT systems are being developed for rapid dynamic imaging
from limited angular views. This work quantified, through simulations, the performance of …

Performance comparison of subtractive resistive readout with conventional resistive readout for a high-resolution compact gamma camera

YJ Qi, MJ Zhang, CL Zhao… - 2007 IEEE Nuclear …, 2007 - ieeexplore.ieee.org
The purpose of this study was to investigate an optimal readout for a high-resolution
compact gamma camera with maximum performance in crystal element identifications. The …