Negative ion beam extraction in ROBIN
G Bansal, A Gahlaut, J Soni, K Pandya… - Fusion Engineering and …, 2013 - Elsevier
The RF based single driver− ve ion source experiment test bed ROBIN (Replica Of BATMAN
like source in INDIA) has been set up at Institute for Plasma Research (IPR), India in a …
like source in INDIA) has been set up at Institute for Plasma Research (IPR), India in a …
Cesium delivery system for negative ion source at IPR
G Bansal, K Pandya, M Bandyopadhyay… - AIP Conference …, 2011 - pubs.aip.org
The technique of surface production of negative ions using cesium, Cs, has been efficiently
exploited over the years for producing negative ion beams with increased current densities …
exploited over the years for producing negative ion beams with increased current densities …
Development of RF driver used in negative ion source at HUST
X Li, D Li, K Liu, X Wang, P Zhao, C Zhou… - Journal of Fusion …, 2015 - Springer
The setting up of RF based negative ion experimental facility shall witness the beginning of
experiments on the negative ion source fusion applications in Huazhong University of …
experiments on the negative ion source fusion applications in Huazhong University of …
RF simulation and improvements of an ion source test facility at HUST
Abstract Huazhong University of Science and Technology is developing a small RF based
ion source for testing key techniques of the negative ion source. Numerical simulations of …
ion source for testing key techniques of the negative ion source. Numerical simulations of …
Conceptual design, implementation and commissioning of data acquisition and control system for negative ion source at IPR
J Soni, R Yadav, A Gahlaut, G Bansal… - AIP Conference …, 2011 - pubs.aip.org
Negative ion Experimental facility has been setup at IPR. The facility consists of a RF based
negative ion source (ROBIN)—procured under a license agreement with IPP Garching, as a …
negative ion source (ROBIN)—procured under a license agreement with IPP Garching, as a …
[PDF][PDF] Gas feed system in negative ion source experimental facility at IPR
G Bansal, KB Pandya, J Soni… - Proceedings of the DAE …, 2011 - iuac.res.in
An inductively coupled RF based (100 kW, 1 MHz) negative hydrogen ion source test bed,
ROBIN, is being set up at IPR under IPR-IPP (Germany) technical collaboration contract. The …
ROBIN, is being set up at IPR under IPR-IPP (Germany) technical collaboration contract. The …
Control system for RF-driven negative ion source experimental setup at HUST
D Li, X Wang, P Zhao, K Liu, L Zhang, H Yue… - Fusion Engineering and …, 2017 - Elsevier
An experimental setup of RF-driven negative ion source has been built at the Huazhong
University of Science and Technology (HUST). The control system for this setup is …
University of Science and Technology (HUST). The control system for this setup is …