The joint evaluated fission and fusion nuclear data library, JEFF-3.3
AJM Plompen, O Cabellos, C De Saint Jean… - The European Physical …, 2020 - Springer
The joint evaluated fission and fusion nuclear data library 3.3 is described. New evaluations
for neutron-induced interactions with the major actinides^ 235 U 235 U,^ 238 U 238 U and …
for neutron-induced interactions with the major actinides^ 235 U 235 U,^ 238 U 238 U and …
The process: Nuclear physics, stellar models, and observations
F Käppeler, R Gallino, S Bisterzo, W Aoki - Reviews of Modern Physics, 2011 - APS
Nucleosynthesis in the s process takes place in the He-burning layers of low-mass
asymptotic giant branch (AGB) stars and during the He-and C-burning phases of massive …
asymptotic giant branch (AGB) stars and during the He-and C-burning phases of massive …
JENDL-4.0: a new library for nuclear science and engineering
K Shibata, O Iwamoto, T Nakagawa… - Journal of Nuclear …, 2011 - Taylor & Francis
The fourth version of the Japanese Evaluated Nuclear Data Library has been produced in
cooperation with the Japanese Nuclear Data Committee. In the new library, much emphasis …
cooperation with the Japanese Nuclear Data Committee. In the new library, much emphasis …
ENDF/B-VII. 1 nuclear data for science and technology: cross sections, covariances, fission product yields and decay data
MB Chadwick, M Herman, P Obložinský, ME Dunn… - Nuclear data sheets, 2011 - Elsevier
The ENDF/B-VII. 1 library is our latest recommended evaluated nuclear data file for use in
nuclear science and technology applications, and incorporates advances made in the five …
nuclear science and technology applications, and incorporates advances made in the five …
Determination of resonance parameters and their covariances from neutron induced reaction cross section data
P Schillebeeckx, B Becker, Y Danon, K Guber… - Nuclear Data …, 2012 - Elsevier
Cross section data in the resolved and unresolved resonance region are represented by
nuclear reaction formalisms using parameters which are determined by fitting them to …
nuclear reaction formalisms using parameters which are determined by fitting them to …
Separation of americium from curium through oxidation state control with record efficiency
Separation of americium (Am) from curium (Cm) could greatly facilitate the development of
advanced nuclear fuel cycles, help with accurate nuclear forensic analysis, and allow for …
advanced nuclear fuel cycles, help with accurate nuclear forensic analysis, and allow for …
[HTML][HTML] Neutron capture measurements with high efficiency detectors and the Pulse Height Weighting Technique
E Mendoza, V Alcayne, D Cano-Ott… - Nuclear Instruments and …, 2023 - Elsevier
Neutron capture cross section measurements in time-of-flight facilities are usually performed
by detecting the prompt γ-rays emitted in the capture reactions. One of the difficulties to be …
by detecting the prompt γ-rays emitted in the capture reactions. One of the difficulties to be …
New Precision Measurements of the Cross Section
M Jandel, TA Bredeweg, EM Bond, MB Chadwick… - Physical Review Letters, 2012 - APS
The neutron capture cross section of U 235 was measured for the neutron incident energy
region between 4 eV and 1 MeV at the DANCE facility at the Los Alamos Neutron Science …
region between 4 eV and 1 MeV at the DANCE facility at the Los Alamos Neutron Science …
Systematics of prompt -ray emission in fission
A Chyzh, CY Wu, E Kwan, RA Henderson… - Physical Review C …, 2013 - APS
The prompt γ-ray energy and multiplicity distributions were measured for the neutron-
induced fission in 235 U and 239, 241 Pu by using a highly segmented 4 π γ-ray calorimeter …
induced fission in 235 U and 239, 241 Pu by using a highly segmented 4 π γ-ray calorimeter …
Measurement and analysis of the neutron capture cross section at the n_TOF facility at CERN
E Mendoza, D Cano-Ott, S Altstadt, S Andriamonje… - Physical Review C, 2018 - APS
The Am 241 (n, γ) cross section has been measured at the n_TOF facility at CERN with the
n_TOF BaF 2 Total Absorption Calorimeter in the energy range between 0.2 eV and 10 keV …
n_TOF BaF 2 Total Absorption Calorimeter in the energy range between 0.2 eV and 10 keV …